USE
1.
This device is suitable for dry and wet
applications
The device must not be switched on without fi lter in
place.
Filter
Electrodes of stainless steel
Wet vacuuming
Remove the dust bag for wet vacuuming.
The device switches off automatically once the
maximum water level has been reached.
The device is not switched off when the tank is
full for non-conductive liquids (such as
emulsion drilling fl uids, oils and greases).
The fi ll level must be monitored continuously and the
tank must be emptied promptly.
NOTE
If water is suctioned quickly, then you will not be
able to suction as much as if water is suctioned
slowly.
The fi lter will get wet when suctioning water.
Ensure that it has suffi cient time to dry and
that all components are completely dry before
using the device for dry vacuuming.
If the water switch-off does not work and fl uid
is suctioned into the motor so that water comes
out of the device, stop the device. Allow the
device to dry suffi ciently.
After wet vacuuming: clean the fi lter after drying it
completely with the fi lter cleaning element. Clean the
electrodes of stainless steel with steel brush if any
contaminations on them. Clean the tank with a moist
cloth and dry it off .
14
Filter holder
Filter screw
Fig. 13
Dry Vacuuming
Vacuum only with dry fi lter, device and accessories.
If the cartridge is damp, dust may stick and form a
crust.
For dry vacuuming dust bags are recommended to
use.
Using as a blower
Use with the fl exible hose inserted into the blow port.
2. Transport
Store the fl exible hose on the housing.
The upper part must be securely sealed to the tank -
check that the clamps are closed.
Set the switch to position "0".
3. Using accessories
When using the wide nozzles and/or tube, we
recommend mounting the nozzle between the
fl exible hose and the wide nozzles/extension wand
in use.
4. Remaining battery indicator
You can check the battery's remaining capacity by
pressing the remaining battery indicator switch to
light the indicator lamp. (Table 5)
It is best to use the remaining battery indicator as
a guide since there are slight diff erences such as
ambient temperature and the condition of the battery.
Also, the remaining battery indicator may vary from
those equipped to a tool or charger.
Remaining battery
indicator lamp
Display panel
Remaining battery
indicator switch
Fig. 14