14
TFM-AN/TFX-AN Series
Networked mains power
TFM-AN loudspeakers also facilitate networked transmission of mains power using power cables with Neutrik powerCON locking power connectors. To set up networked
mains power between TFM-AN loudspeakers, first run a power cable terminating in a powerCON connector to the AC INPUT connector on the rear panel.
To power additional speakers downline, run power cables equipped with powerCON connectors at both ends from the first speaker's AC LINK OUTPUT to the AC INPUT of
the next TFM-AN loudspeaker in series.
The maximum number of linked systems depends on the AC supply voltage as well as the maximum current draw of the individual systems in the power chain.
When linking a power chain, make sure that the integrated connectors as well as the supplied AC mains cable are never overloaded. If you are uncertain how to calculate
the total current draw, please contact your dealer.
TFM-AN speakers powered in series
TFM-AN/TFX-AN DSP Menu Structure
Fullrange
None
PROCESS
EQ
Vocal
Speech
Playback
User
None
XOVER
HP 120 Hz
HP 100 Hz
User
Freq
Sub Menu
Phase
Auto
FBQ
Single
Learn
Reset
Input
SETUP
INPUT
(page 1)
Volume
Stand
POSITION
Floor
Corner
Delay
DELAY
Unit
Limit
LIMITER
Quick Start Guide
Function
Sets the frequency response to the default setting.
Sets the frequency response to give an ideal monitor speaker for vocals.
Sets the frequency response for optimal speech intelligibility.
Sets the frequency response ideal for music playback.
Lets you define your own frequency response setting by entering the corresponding sub-menu.
Unit is set for default full-range / subwoofer reproduction.
Preset with 120 Hz, 24 dB/octave filter for crossover between subwoofer and full-range speakers.
Preset with 100 Hz, 24 dB/octave filter for crossover between subwoofer and full-range speakers.
User crossover sub menu for combination with other full-range or subwoofer speaker systems.
Select the desired crossover frequency:
Fullrange systems: 75 Hz to 400 Hz.
Adjust the absolute phase (0° or 180°).
Automatically sets as many filters as required. Whenever a new feedback frequency is discovered,
the first filter will be released to attenuate the new frequency, and so forth.
Activates the FBQ (feedback detection) functionality, up to 8 feedback filters.
Automatic procedure which searches for feedback frequencies and locks settings after all
8 filters have been set.
WARNING!
Please use ear protection during this procedure. The feedback signal may approach
the system's maximum level, which may cause hearing damage!
Resets all filters.
Lets you choose the audio input source. Choose between Local (analogue Input) or ULTRANET
(e.g., P16 monitoring system or M32 audio via ULTRANET).
Adjusts the input gain. With ULTRANET digital inputs over a range from +10 dB to -30 dB.
With analogue input from 0 dB to -∞ dB.
For positioning the speaker on a pole mount stand (full-range) or on the floor (subwoofer).
For positioning the speaker on the floor as a monitor speaker (wedge).
For positioning the speaker in a corner next to the ceiling (fixed install); For positioning the
speaker in a corner (subwoofer).
Adjusts the amount of delay (max 300msec = 103.08m or 338.19 feet).
Selector between msec, meter and feet.
Adjust the limiter threshold for the input signal (from OFF down to -30 dB). This threshold
adjustment allows you to set a max output power which is below the speaker system's
rated max output.