Welcome to use SG20-00030 smoke alarm!
They are photoelectric smoke alarms, and they are generally more effective at detecting smoldering fires which has
smoldered for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or
TECHNICAL PARAMETER:
Power: 9V/DC
Working Consumption: <10mA
Working temperature:-20ºC~40ºC
WHERE TO INSTALL SMOKE ALARMS:
1. At first, you need to install them in your bedroom and route way, and
should install at least one item in every bedroom.
2. Stairway is important for you to rush out when fires occur, so smoke
detectors must be installed there as Diagram 1 shows.
3. You at least require one smoke alarm on every floor, including
finished attics and basements.
4. Install one alarm beside every electric facility.
5. Install smoke alarms in the middle of ceiling, because smog, heat
and flashes are always through the roof of rooms.
6. If some reasons cause you can't install them in the middle of ceiling,
you need to install them at least 10cm away from the wall.
7. If you like to install them on the wall, they should be installed
10-30.5cm away under the ceiling as Diagram 2 shows.
8. You need to install more than one alarm when the length of your hall
exceeds 9m.
9. In a triangle roof room, install the alarm 0.9m away from the top as
Diagram 3 shows.
10. How to install smoke alarms in a removable house. The removable
house is short of heat isolation, so you'd better install the alarm
10-30.5cm away from the ceiling. For safety you also need install
another one near your bedroom.
WHERE NOT TO INSTALL SMOKE ALARMS:
1. Where combustion particles are produced. Combustion particles form when something burns. Avoid Installing in the
areas including poorly ventilated kitchens, garages, and furnace rooms. Keep units at least 6m from the sources of
combustion particles (furnace, water heater, space heater) if possible. Ventilate these areas as much as possible.
2. In air streams near kitchens. Air currents can draw cooking smoke into the sensing chamber of a smoke alarm near
the kitchen.
3. In very damp or steamy areas, or near bathrooms with showers .Keep units at least 3m away from showers, saunas,
dishwashers etc.
4. Where the temperatures are regularly below 40 F (4ºC) or above 100F (38ºC), including unheated buildings, outdoor
rooms, porches, or unfinished attics or basements.
5. In very dusty, dirty or greasy areas. Don't install a smoke alarm directly over the stove or its range. Clean a laundry
room unit frequently to keep it free of dust or lint.
6. Near fresh air vents, ceiling fans, or in very drafty areas. Wind can blow smoke away from the unit, preventing it from
reaching the sensing chamber.
7. In insect infested areas. Insects can clog openings to the sensing chamber and cause unwanted alarms.
8. Less than 30mm away from fluorescent lights. Electrical "noise" can interfere with the sensor.
9. In "dead air" space, for example, in Diagram 2, near the corner less than 10cm.
10. If you have a smoking meeting room, don't install the alarm there for the unit will alarm when several persons smoke.
INSTRUCTION
Smoke Alarm
Static Consumption: < 8uA
Alarm sound: ≥ 85 db (3m)
BEDROOM
MULTIPLE FLOOR PLAN
SINGLE FLOOR PLAN
KITCHEN
BEDROOM
BEDROOM
LIVING ROOM
BEDROOM
SMOKE ALARM FOR MINIMUM PROTECTION
SMOKE ALARM FOR ADDITIONAL PROTECTION
DIAGRAM 1
10CM(4'')
CEILING
MINIMUM
BEST HERE
NEVER HERE
ACCEPTABLE HERE
DIAGRAM 1
SIDE WALL
BEDROOM
BEDROOM
KITCHEN
BASEWENT
DIAGRAM 2
DIAGRAM 3