Descargar Imprimir esta página

Oase Bitron Eco 120 W Instrucciones De Uso página 46

Ocultar thumbs Ver también para Bitron Eco 120 W:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 105
Cleaning/replacing the quartz glass
CAUTION
The quartz glass and UVC lamp could break and result in cuts.
Carry out all work on the UVC clarifier carefully to avoid cutting injuries.
Avoid vibrations, impacts and hectic movements to prevent the breaking of glass.
NOTE
The unit may be damaged, if the water flow is suddenly interrupted downstream of the outlet
(e.g. by a slide valve). The sudden interruption can cause a temporary pressure increase of over 1
bar (hydraulic shock).
Switching off: First switch off the pump, then close the slide valve. If the unit is operated in a
filter system, first take the filter system out of operation.
Switching on: First open the slide valve, then switch on the pump. If the unit is operated in a
filter system, start up the filter system last.
As an alternative, install the slide valve upstream of the inlet.
Prerequisite:
 The unit head is removed. (→ Dismantling the unit head)
46
BTN0002

Publicidad

loading

Este manual también es adecuado para:

Bitron eco 180 wBitron eco 240 w