Descargar Imprimir esta página

Comunello CU 230V HP Instrucciones De Uso Y De Instalacion página 26

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 45
1 (alternate blinking 1 0 1 0 1 0 of menu LED LEV) and then use the SEL key
to select blinking LED L5 and press the SET key; LED L5 becomes steady
on and the operation will be completed. Repeat the procedure if you wish
to restore the initial configuration.
6. DS1 PARTIAL REVERSAL:
The control unit allows the operation of input DS1 to be modified. If, during
a closing manoeuvre, you want DS1 to perform a partial reversal (short
reversal) of the gate leaf instead of a total reversal, proceed as follows:
ensure you have enabled Extended Menu 1 (alternate blinking 1 0 1 0 1
0 of menu LED LEV) and then use the SEL key to select blinking LED L6
and press the SET key; LED L6 becomes steady on and the operation
will be completed. Repeat the procedure if you wish to restore the initial
configuration.
7. EMERGENCY STOP / 8K2:
The control unit allows the connection of an NC Emergency Stop
pushbutton (CN2 input LED LEV). However, this input can be switched to
an 8.2 KOhm resistive input: ensure you have enabled Extended Menu 1
(alternate blinking 1 0 1 0 1 0 of menu LED LEV) and then use the SEL key
to select blinking LED L7 and press the SET key; LED L7 becomes steady
on and programming will be completed. A change of the value read on
the input will cause the control unit to shut down irrespective of the gate
movement currently in progress. An additional gate movement command
will be valid provided the correct input value is restored and irrespective of
the prior status the control unit will execute the gate opening cycle. Repeat
the procedure if you wish to restore the initial configuration.
EXTENDED MENU 2
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 2, proceed
as follows: select blinking LED LEV and press SET twice. The LED will
start blinking alternately 1 1 0 1 1 0. This means there will be 30 seconds
to select the functions of Extended Menu 2 using the SEL and SET keys;
once an additional 30 seconds have elapsed, the control unit reverts to the
main menu.
L1
BRAKE
L2
DECELERATION
L3
ALWAYS CLOSE
L4
FOLLOW ME
L5
PEDESTRIAN TIME
L6
2
nd
CH MONOSTABLE
L7
REMOTE PRG
LEV
MENU LEVEL
1. BRAKE:
The control unit is factory set with the electronic brake function disabled.
If you wish to enable the function, proceed as follows: ensure you have
enabled Extended Menu 2 (alternate blinking 1 1 0 1 1 0 1 1 0 of menu
LED LEV) and then use the SEL key to select blinking LED L1 and press the
SET key; LED L1 becomes steady on and the operation will be completed.
With the brake enabled the control unit reduces coasting of the gate due
to inertia at the time of a stop or direction reversal command. Repeat the
procedure if you wish to restore the previous configuration.
2. DECELERATION:
As indicated above, the control unit allows a deceleration stage to be
programmed during opening and closing, while with the Automatic
Programming function the deceleration stage is included automatically.
However, if no deceleration stage is required it can be excluded. In this
manner, when using Automatic Programming the Deceleration stage will no
longer be included, while if the Motor Times Programming function is used
the option of programming a deceleration stage during opening and closing
will no longer be available. If, before excluding the deceleration stage it had
already been programmed using the Motor Times Programming function,
programming must be repeated from the beginning. If you wish to exclude
the deceleration stage proceed as follows: ensure you have enabled
Extended Menu 2 (blinking 1 1 0 1 1 0 of LED LEV) and then use the SEL
key to select blinking LED L2 and press the SET key; LED L1 becomes
steady on and the operation will be completed. Repeat the procedure if you
wish to restore the previous configuration.
26
COMUNELLO ®Copyright 2014 - All right reserved
ON
OFF
OFF
ON
ON
OFF
ON
OFF
PGM TIME
10 Sec
ON
OFF
ON
OFF
2 FLASHIES
3. ALWAYS CLOSE:
The control unit allows to set "Always Close" operation: this function, which
is programmable only if a Pause Time has already been programmed, is
activated after a power loss; if the gate open condition is confirmed a closing
movement is started automatically, preceded by 5 seconds of preflashing.
If you wish to exclude the deceleration stage proceed as follows: ensure
you have enabled Extended Menu 2 (blinking 1 1 0 1 1 0 of LED LEV) and
then use the SEL key to select blinking LED L3 and press the SET key; LED
L3 becomes steady on and the operation will be completed. Repeat the
procedure if you wish to restore the previous configuration.
4. FOLLOW ME:
The control unit allows the "Follow me" function to be configured;
programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 5 seconds after freeing the DS1 photocell,
meaning the gate re-closes 5 seconds after transit of the user. To activate
this function, proceed as follows: ensure you have enabled Extended
Menu 2 (blinking 1 1 0 1 1 0 of LED LEV) and then use the SEL key to
select blinking LED L4 and press the SET key; LED L4 becomes steady on
and the operation will be completed. Repeat the procedure if you wish to
restore the previous configuration.
5. PED. MOT. T: (Programming of pedestrian opening motor time of
max 4 minutes)
The control unit is factory set with Motor time (Pedestrian opening) of 10
seconds without deceleration.
If the pedestrian run time must be changed, programming must be carried
out with the gate closed as follows: ensure you have enabled Extended
Menu 2 (blinking 1 1 0 1 1 0 of LED LEV) use the SEL key to select blinking
LED L5 and then press the SET key momentarily; the Operator will start
the opening movement; when the required deceleration starting point is
reached, press the SET key again; LED L5 will start blinking more slowly
and the Operator will decelerate; on reaching the required poisition press
SET to terminate the Opening cycle. At this point LED L5 returns to the
normal blinking speed and the Operator restarts in the Closing movement;
repeat the operations described above for the Closing movement.
If you do not require the control unit to perform the deceleration, during
programming, when the opening and closing cycle has been completed
press the SET key twice consecutively rather than just once.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand.
6. AUXILIARY RADIO CHANNEL OPERATING LOGIC:
(2
CH monostable)
nd
The control unit allows the operating logic of the Auxiliary Radio Channel
to be selected.
The control unit is factory set with "Monostable" operation of the Auxiliary
Radio Channel. If you wish to enable "Bistable" operation proceed as
follows: ensure you have enabled Extended Menu 2 (blinking 1 1 0 1 1
0 of LED LEV) and then use the SEL key to select blinking LED L6 and
press the SET key; LED L6 becomes steady on and the operation will be
completed. If you wish to enable "3 Minutes Timed" operation, repeat the
operation described above; pressing the SEL key twice (LED L6 will blink
rapidly) rather than once. Repeat the procedure if you wish to restore the
initial configuration.
7. REMOTE RADIO CONTROL PROGRAMMING:
The control unit allows the transmission code to be programmed remotely
without acting directly on the control unit SEL key.
Remote programming of a Radio remote control is performed as follows:
send, continuously for a time in excess of 10 seconds, the code of a
previously saved remote control; at the same time the control unit switches
to programming mode as described above for the LED L2 in the main
menu. If a previously saved pedestrian code is transmitted continuously
the control unit will enter programming mode of a new pedestrian code and
LED L2 will blink as though acquisition of the pedestrian code were active
(1 1 0 1 1 0 1 1 0); if the code is associated with the 2
LED will blink as though acquisition of the 2
0 1 1 1 0 1 1 1 0). To enable the remote programming function, proceed
as follows:
ensure you have enabled Extended Menu 2 (blinking 1 1 0 1 1 0 of LED
LEV) and then use the SEL key to select blinking LED L7 and press the
SET key; LED L7 becomes steady on and the operation will be completed.
Repeat the procedure if you wish to restore the initial configuration.
nd
CH/AUX input the
CH code were active (1 1 1
nd

Publicidad

loading