Product Information
2.3
Simplified UK/EU Declaration of conformity
regarding radio equipment
Bosch Thermotechnik GmbH hereby declares, that the Climate 2000
product described in these instructions complies with the Directive UK
S.I. 2017/1206 (UK) 2014/53/EU.
You can request the complete text of the UK/EU Declaration of
Conformity from the UK address indicated in this document.
2.4
Regulations
In order to ensure installation and operation of the product in
accordance with the regulations, please observe all the applicable
national and regional regulations as well as all technical rules and
guidelines.
You can find a list of the most relevant British and European directives
and regulations in the table below.
EU legislation
Electromagnetic Compatibility -
Directive 2014/30/EU
Low Voltage Directive 2014/35
Radio Equipment -
Directive 2014/53/EU
Pressure Equipment -
Directive 2014/68/EU
Gas Appliances -
Regulation (EU) 2016/426
Machinery Directive 2006/42/EC Supply of Machinery (Safety)
Ecodesign Directive 2009/125/
EC
Energy Labelling Regulation (EU)
2017/1369
Restriction of the Use of certain
Hazardous Substances in Eletrical
and Electronic Equipment (RoHS)
- Directive 2002/95/EC
European Directive 2012/19/EC
on old electronic and electrical
appliances
Table 29
2.5
Scope of delivery
Key to figure 52:
[1]
Outdoor unit (filled with refrigerant)
[2]
Indoor unit (filled with nitrogen)
[3]
Cold catalyst filter
[4]
Drainage elbow with gasket (for outdoor unit with floor or wall
mounting bracket)
[5]
Remote controller
[6]
Remote control holder with fixing screw
[7]
Fixing materials (5 screws and 5 wall plugs)
[8]
Set of printed documents for product documentation
[9]
5-wire communication cable (optional accessory)
[10] 4 anti-vibration couplings for the outdoor unit
[11] Magnetic ring and belt
2.6
Product dimensions and minimum clearances
2.6.1
Indoor unit and outdoor unit
Figures 53 to 55.
26
UK legislation
Electromagnetic Compatibility
Regulations 2016
Electrical Equipment (Safety)
Regulations 2016
Radio Equipment Regulations
2017
Pressure Equipment (Safety)
Regulations 2016
Regulation 2016/426 on gas
appliances as brought into UK law
and amended
Regulations 2008
The Ecodesign for Energy-Related
Products Regulations 2010
Energy Labelling Regulation (EU)
2017/1369 (as retained in UK law
and amended)
The Restriction of the Use of
Certain Hazardous Substances in
Eletrical and Electronic Equipment
Regulations 2012
(UK) Waste Electrical and
Electronic Equipment Regulations
2013 (as ammended)
2.6.2
Refrigerant pipes
Key to Fig. 56:
[1]
Gas-side pipe
[2]
Liquid-side pipe
[3]
Siphon-shaped elbow as oil separator
If the outdoor unit is positioned higher than the indoor unit, install a
siphon-shaped elbow on the gas side after no more than 6 m and every
6 m thereafter ( Fig. 56, [1]).
▶ Observe maximum pipe length and maximum difference in height
between indoor unit and outdoor unit.
Maximum pipe
length
CL2000 26 E
CL2000 35 E
CL2000 53 E
CL2000 70 E
1) Gas side or liquid side
2) Measured from bottom edge to bottom edge.
Table 30 Pipe length and difference in height
Unit type
Liquid side [mm]
CL2000 26 E
6.35 (1/4")
CL2000 35 E
6.35 (1/4")
CL2000 53 E
6.35 (1/4")
CL2000 70 E
9.53 (3/8")
Table 31 Pipe diameter depending on appliance type
Pipe diameter [mm]
6.35 (1/4")
9.53 (3/8")
12.7 (1/2")
15.9 (5/8")
Table 32 Alternative pipe diameter
Specification of the pipes
Min. piping length
Standard piping length
Additional refrigerant if the pipe length
exceeds 5 m (liquid side)
Pipe thickness with 6.35 mm to 12.7 mm
pipe diameter
Pipe thickness with 15.9 mm pipe
diameter
Thickness of heat insulation
Material of heat insulation
Table 33
2.6.3
Protection zone
The product contains the refrigerant R32, which is denser than air. If the
refrigerant leaks, it could accumulate near the ground. The refrigerant
must therefore not be allowed to accumulate in recesses, drains or gaps
in the building.
There must be no openings in the building, such as air ducts, hatches,
valves, downpipes, cellar entrances, windows or doors, within the
Maximum difference
1)
2)
[m]
in height
≤ 25
≤ 10
≤ 25
≤ 10
≤ 30
≤ 20
≤ 50
≤ 25
Pipe size
Gas side [mm]
9.53 (3/8")
9.53 (3/8")
12.7 (1/2")
15.9 (5/8")
Alternative pipe diameter [mm]
6
10
12
16
3 m
5 m
With Ø 6.35 mm (1/4"):
12 g/m
With Ø 9.53 mm (3/8"):
24 g/m
≥ 0.8 mm
≥ 1.0 mm
≥ 6 mm
Polyethylene foam
Climate 2000 – 6721852025 (2024/01)
[m]