TANK AND RESET THE HEATER (SEE PAR.
en
7.2.).
IMPORTANT:
it
combustion products are directed outside
de
through suitable chimney. CARRY OUT
THE CHIMNEY IN ACCORDANCE WITH
es
CURRENT SAFETY REGULATIONS AND
FOLLOW THE INSTRUCTIONS IN THE
fr
RELEVANT SECTION OF THE MANUAL.
nl
►►7.2. RESETTING THE HEATER:
pt
The appliance stops when an anomaly occurs.
The reset button turns on with a steady red light
da
(PIC. 17), it means the heater needs to be reset.
fi
To reset the heater, press the reset button all
the way down (PIC. 18). Identify and remove
no
the cause that stopped the appliance (for
instance, obstruction of air intake and/or outlet,
sv
total block of the fan, etc.). Please contact an
pl
appointed service center for assistance in case
it is impossible to solve the problem.
ru
►►7.3. SWITCHING OFF THE HEATER:
cs
Set the "I/0" button to "0" (PIC. 19). Flames
hu
extinguish and the fan keeps on working until
the combustion chamber has fully cooled down.
sl
Do not pull the plug out until the cooling
cycle has totally ended.
tr
8. CLEANING THE FILTERS
hr
THE FILTERS MAY NEED TO BE CLEANED
lt
DEPENDING ON THE QUALITY OF THE
FUEL USED.
lv
►►8.1. FUEL TANK FILTER (PIC. 20):
et
►8.1.1. Remove tank (A) cap.
ro
►8.1.2. Take out the filter (B) from the tank.
►8.1.3. Clean the filter (B) with clean fuel,
sk
without damaging it.
►8.1.4. Put the filter (B) back in the tank.
bg
►8.1.5. Close cap (A).
uk
►►8.2. INTAKE FILTER, (PIC. 21)
bs
DEPENDING ON THE MODEL:
►8.2.1. Take out the filter (A).
el
►8.2.2. Remove the pipe-clamping straps (B).
►8.2.3. Take out the pipes (C).
zh
►8.2.4. Replace the filter (A) with an original
spare part.
►8.2.5. Put the pipes (C) back.
►8.2.6. Put the pipe-clamping straps (B) back.
►8.2.7. Put the filter (A) back into its original
position.
In
indirect
models,
►►8.3. INTAKE FILTER, (PIC. 22)
DEPENDING ON THE MODEL:
►8.3.1. Remove the cup (A).
►8.3.2. Take out the filter (B) from the cup.
Keep gaskets for later use.
►8.3.3. Clean the filter (B) with clean fuel,
without damaging it.
►8.3.4. Put the filter (B) back in the cup.
►8.3.5. Put the glass (A) back on and
reassemble the gaskets correctly.
►►8.4. FUEL PUMP FILTER:
See the preventive maintenance schedule.
9. STORAGE AND TRANSPORT
WARNING: Before moving the appliance,
the heater must be stopped (SEE PAR.
7.3.) and disconnected from the power
supply by pulling out the plug (PIC. 23),
wait for a complete cool down and close
the tank cap properly to prevent fuel
leakage. Keep the heater in horizontal and
stable position during transport.
IN ORDER TO KEEP THE HEATER IN
THE BEST POSSIBLE CONDITIONS, WE
RECOMMEND TO FOLLOW THE BELOW
PROCEDURE:
►9.1. Empty the fuel by removing the drain
cap at the bottom of the tank (PIC. 24-25).
Dispose the fuel in an appropriate container
in accordance with the current safety
regulations.
►9.2. To remove any residual remaining, pour
clean fuel and rinse the tank again.
►9.3. Close the drain cap and the tank cap.
►9.4. In order to keep the heater in the best
possible conditions, we recommend placing it
in a dry and safe place.
10. CONNECTING THE ROOM
THERMOSTAT
In models with a thermostat connection, remove
the cap connected to the appliance and connect
the room thermostat (optional) (SEE PIC. 26-
27).