8.5
Continuous mode
To switch the machine to continuous mode, keep the on/off switch pressed and at the same
time press the lock-on button (5). Subsequently release the on/off switch.
To switch off continuous mode, press the on/off switch again.
Never put down the machine when using the continuous mode!
9 CLEANING AND MAINTENANCE
Before performing any work on the equipment, pull the power plug.
9.1
Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These solvents may
damage the plastic parts.
9.2
Maintenance
Our machines have been designed to operate over a long period of time with a minimum of
maintenance. Continuous satisfactory operation depends upon proper machine care and
regular cleaning.
10 TECHNICAL DATA
Voltage / Frequency
Input power
Chuck capacity
No load speed
Capacity concrete
Capacity steel
Capacity wood
11 NOISE
The declared vibration total value has been measured in accordance with a standard test
method and may be used for comparing one tool with another.
The declared vibration total value may also be used in a preliminary assessment of exposure.
The vibration emission during actual use of power tool can differ from the
declared total value depending on the ways in which the tool is used.
The safety measures to protect the operator are identified based on an
estimation of exposure in the actual conditions of use.
Copyright © 2024 VARO
POWC10110
220-240V ~ 50Hz
550W
Max.13mm
0 – 3000/min
10mm
6mm
13mm