Risk of Breathing
Risk of
Electrical Shock
Risk of
Explosion
or Fire
Risk of Bursting
Avoid using the air compressor in confined areas. Always have adequate space
(12 inches) on all sides of the air compressor. Also keep children, pets, and others out
of the area of operation. This air compressor does not provide breathable air for anyone
or any auxiliary breathing device. Spraying matedaTwill always need to be in another
area away from the air compressor to net allow intake air to damage the air compressor
fitter,
Never utilize the air compressor in the rain or wet conditions. Any electrical issues
or repairs should be performed by authorized personnel such as an electrician and
should comply with all national and local electrical codes. The air compressor should
also have the proper three prong groundirig plug, correct voltage, and adequate fuse
protection.
Never operate the compressor near combustible materials, gasoline or solvent vapors.
If spraying flammable materials, locate the air compressor at least 20 feet away from
the spray area. Never operate the air compressor indoors or in a confined area.
Always drain the air compressor
tank daily or after each use. If the tank develops
a leak,
then reptace the air compressor.
Never use the air compressor
after a leak has been
found or try to make any modifications
to the tank. Never modify
the air compressor's
factory settings
which control the tank pressure
or any other function.
Specifications
Pump ..........................
Oil-lube direct drive
Motor ...........................
1.0 HP (Induction)
Bore .......................................
1.65_
Stroke ......................................
126"
Voltage Single Phase .......................
120 VAC
Minimum Circuit Requirement ................
15 Amps
Air Tank Capacity .........................
7 Gallons
Cut-in Pressure .............................
95 PSI
Cut-out Pressure ...........................
125 PSI
SCFM @ 90 PSI................................
24
Oil Capacity .........................
90 mL or 3 oz.
Oil Type .........................
SAE 30 Non-detergent
Glossary
CFM:
Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure
for air delivery.
PSIG:
Pounds per square inch gauge; a unit of measure
for pressure.
ASME: American Society of Mechanical Engineers.
California Code: Unit may comply with California Code
462 (I) (2)/(U) (2).
Cut-In Pressure:
The air compressor will automatically
start to refill the tank when the pressure drops
below the prescribed minimum.
Cut-Out Pressure: The point at which the motor stops
when the tank has reached maximum air
pressure,
Code Certification:
Products that bear one or more sf
the following marks: UL, ULc, ETL, CSA, have
been evaluated by OSHA-certified independent
safety laboratories and meet the applicable
Underwriters Laboratories Standards for Safety.
Duty Cycle
This is a 50% duty cycle air compressor. Do not run the air compressor more than 30 minutes of one hour. Doing so
could damage the air compressor.