OUTSIDE CABINET
Be sure that the unit has access to ample air. Avoid hot corners and locations near
stoves and ovens. It is recommended that the unit be installed no closer than 2"
from any wall with at least 12" of clear space above the unit. Should it become
necessary to lay the unit on its side or back for any reason, allow at least 24 hours
before start-up so as to allow compressor oil to flow back to the sump. Failure to
meet this requirement can cause compressor failure and unit damage.
LEVELING
A level cabinet looks better and will perform better because the doors will line up
with the frames properly, the cabinet will not be subject to undue strain and the
contents of the cabinet will not move around on the shelves. Use a level to make
sure the unit is level from front to back and side to side. Units supplied with legs
will have adjustable bullet feet to make the necessary adjustments. If the unit is
supplied with casters, no adjustments are available. Ensure the floor where the
unit is to be located is level.
STABILIZING
Models are supplied on casters for your convenience, ease of cleaning
underneath and for mobility. It is very important, however, that the cabinet be
installed in a stable condition with the front wheels locked while in use.
ELECTRICAL CONNECTION
Refer to the amperage data on page 5, the serial tag, your local code or the
National Electrical Code to be sure the unit is connected to the proper power
source. A protected circuit of the correct voltage and amperage must be run for
connection of the line cord, or permanent connection to the unit.
OPERATION
CAUTION: DO NOT THROW ITEMS INTO THE STORAGE AREA. FAILURE TO HEED THESE
RECOMMENDATIONS COULD RESULT IN DAMAGE TO THE INTERIOR OF THE
CABINET.
The factory setting for the temperature range is 34°F to 38° F which keeps your
product at a safe, cold temperature. A light switch is located next to on/off switch
on the front of the bottom shroud.
CONTROL PANEL SOLID-STATE THERMOSTAT
FRONT PANEL COMMANDS
SET
SET: To display target set point; in programming mode it selects a
parameter or confirms an operation.
DEF: To start a manual defrost
UP: To view the last alarm occurrence; in programming mode it browses
the parameter codes or increases the display value
DOWN: To view the last alarm occurrence; in programming mode it
browses the parameter codes or decreases the display value
3
BACK BAR BOTTLE COOLER
Key Combination:
To lock & unlock the keyboard
To enter in programming mode
To return to the room temperature display
LED
MODE
On
Compressor enabled
Flashing
Anti-short cycle delay enabled (AC parameter)
On
Defrost in progress
Flashing
Dripping in progress
On
Measurement unit
Flashing
Programming mode
On
Measurement unit
Flashing
Programming mode
MAIN FUNCTIONS
1. How to See the Setpoint
1. Push and immediately release the SET key: the display will show the set
point value.
2. Push and immediately release the SET key or wait for 5 seconds to display
the sensor value again.
2. How to Change the Setpoint
1. Hold the SET key for more than 2 seconds to change the set point value.
2. The value of the set point will be displayed and the
3. To change the set value, push the
4. To set new point value, push the SET key again or wait 10 seconds.
3. How to Start a Manual Defrost
1. Hold the
key for more than 2 seconds and a manual defrost will start.
4. How to Lock the Keyboard
1. Hold the
and
keys for more than 3 seconds.
2. The "POF" message will be displayed and the keyboard will be locked. At
this point, it will be possible only to see the set point or the MAX or MIN
temperature stored.
3. If a key is pressed for more than 3 seconds, the "POF" message will be
displayed.
5. How to Unlock the Keyboard
1. Hold the
and
keys together for more than 3 seconds, until the "POF"
message is displayed.
ALARM SIGNALS
How to See the Alarm and Reset the Recorded Alarm
1. Push the
or
key to display the alarm signals.
2. When the signal is displayed, hold the SET key until the "rst" message is
displayed. Push the SET key again. The "rst" message starts blinking and the
normal temperature will be displayed again.
MESSAGE
CAUSE
"P1"
Room probe failure
"P2"
Evaporator probe failure
"HA"
Maximum temperature alarm
"LA"
Minimum temperature alarm
"dA"
Door open
"EA"
External alarm
"CA"
Serious external alarm (i1F=bAL)
FUNCTION
LED starts blinking.
or
key within 10 seconds.
OUTPUTS
Compressor output according
to par. "Con" and "COF"
Defrost end is timed
Outputs unchanged
Outputs unchanged
Compressor and fans restarts
Output unchanged
All outputs OFF