MODEL NUMBER
36600-0000
36600-0010
SERVICE
— See Figure 2.
1. Turn off power to pump. Remove four tie down bolts.
2. Lift jack shaft and the attached diaphragm assembly from
pump base.
3. Remove two diaphragm retainer screws and the diaphragm
retainer.
4. Remove lock nut. Remove connecting rod and diaphragm
from jack shaft, then unscrew bolt to separate diaphragm and
plates.
5. Check diaphragm for cuts and cracks. Check rod assembly
bearing for excessive wear. Replace if badly worn.
6. Loosely reassemble diaphragm, diaphragm plates, washer and
diaphragm bolt onto connecting rod. Firmly secure connecting
rod to jack shaft with the lock nut. Secure diaphragm to motor
mount with the diaphragm retainer and two screws.
7. Tighten connecting rod bolt.
VALVE REPLACEMENT
1. Turn off power to pump. Remove four tie down bolts.
2. Expose valves by lifting jack shaft and attached diaphragm as-
sembly from pump base. Remove and clean or replace valves.
3. Install valves, making sure rubber flapper is UP on intake and
DOWN on discharge.
4. Replace motor-mount-diaphragm assembly and fasten evenly
to base with the four tie down bolts.
DIMENSIONS
Dimensions Pouces (Millimètres) / Abmessungen Zoll (Millimeter) / Dimensioni Pollici (millimetri) / Afmetingen Inch (Millimeters)
Mått tum (millimeter) / Dimensiones pulgadas (milímetros)
ELECTRICAL SPECIFICATIONS - MINIMUM WIRE SIZES
VOLTAGE
12 Vdc
24 Vdc
*Customer supplied, not included with pump.
— See Figure 2.
Inches (Millimeters)
Wire size for length of run
1–25'
12 AWG
14 AWG
PULSATION DAMPENERS REPLACEMENT
— See Figure 2.
1. Disconnect power leads from pump and remove from mount.
2. Remove nine bottom cap screws and three bottom plate
screws. Remove bottom cap and plate. Pull out and replace
pulsation dampeners.
3. Replace bottom cap, plate and screws. Tighten evenly to
ensure air and water seals.
4. Reinstall pump and reconnect power leads.
TROUBLESHOOTING
PROBLEM
Loss of suction
to pump.
Rough or noisy
operation.
CAUTION: POTENTIAL FOR COMPONENT
INCOMPATIBILITY - FOR WATER ONLY
CAUTION: MOTOR BASE COULD GET HOT DURING
EXTENDED OPERATION. PROLONGED CONTACT WITH
SKIN MAY CAUSE BURN
3
FUSE/BREAKER*
25–50'
10 AWG
14 AWG
SOLUTION
-Air leak in suction line.
-Bilge pickup not submerged.
-Intake hose kinked or plugged.
-Fouled intake or discharge valve.
-Ruptured diaphragm.
-Intake or discharge hose kinked or plugged.
-Pump not mounted firmly.
-Loosened eccentric screw.
-Ruptured or collapsed pulsation dampener.
15 amp
8 amp