Never open the appliance outdoors during rain or
storms.
Never sit or stand on the appliance.
Arrange the cables and hose so that no-one can
trip over them.
The appliance must not be operated in areas with
an explosion hazard.
Never insert or remove the mains plug with wet
hands.
Only pull on the mains plug, not on the lead.
IMPORTANT - This machine must only be stored
indoors.
Ensure that the vacuum cleaner is steady.
Warning sign for machines with dust class M:
5 Overview
See page 3 (please unfold).
1 Rotary switch volumetric flow setting
2 Rotary switch on/off/automatic/vibrator
3 Volumetric flow control display
4 Plug socket for power tool
5 Carrying handle
6 Upper part
7 Locking bar
8 Locking button
9 Suction opening
10 Container
11 Snap lock
12 Paper filter bag
13 Motor protection filter
14 Filter cassettes (complying with BIA C)
6 Initial Operation
Before plugging in check to see that the
rated mains voltage and mains frequency,
as stated on the rating label, match with your
power supply.
6.1
Attaching the carrying handle
Stick the carrying handle (5) into the support
provided for it on the container (10) and secure
with the quick-release locks provided.
6.2
Fitting wheels (if necessary)
Insert the axles of the guide rollers in the holes in
the container until they engage.
Fit the large wheels as shown:
7 Use
7.1
On/Off Switch, automatic, vibrator
Select the mode via switch (2):
0 = Vacuum cleaner off
I
= Dust extractor on (manual operation; use as
industrial dust extractor)
A = Automatic On/Off switch.
(Use as dust remover) Dust extractor is
turned on and off by a power tool
connected to the mains socket (4).
R = Electromagnetic vibrator on.
Dust is shaken off the filter.
The vibrator switches off automatically after
approx. 10 secs.
The power socket (4) is designed for
connection to a power tool only.
The total maximum permissible current
consumption (of dust extractor and
connected unit) must not exceed the value I
(see table, page 2).
Caution! The power tool must be switched
off when it is connected. Regardless of
the switch position the plug socket is always
live when the mains plug is plugged in.
In switch position "0" the plug socket can be used
as an extension lead (e.g. for a lighting fitting).
7.2
Selecting the operating mode
Use as industrial dust extractor (IDE):
Set the rotary switch (2) to "I" (manual mode).
Set the rotary switch (1) to a volumetric flow
setting of 70 m³/h.
If the air speed in a tube system 35 mm in diameter
falls below the average air speed of 20 m/s, the
volumetric flow control display (3) blinks. This
indicates that the paper filter bag must be changed
or the vibration equipment activated.
Use as dust remover (DR):
The dust remover must be connected to only one
dust source.