Keypad
Program 6
Changing the control time - lock-out time
Enter 8 digit
mastercode
Enter 3 digit
time 001-255
*Lock-out time:
dynamic = The lock-out time is extended by 10 sec. with
every wrong entry (max. 255 sec.)
static = The lock-out time is always the set time (000 = turned off)
Program 8
Entering a pass code
Enter 4 or 5 digit
pass code
A correct code is detected; the corresponding relay is switched!
Before the actual pass code, you can press any other keys to prevent fraud.
If an incorrect pass code is entered, you will hear a sound signal (3 beeps).
Entering a new pass code is only possible after the lock-out period (factory: 20 sec.) which end
push
button
The modified lock-out time is saved!
push
button
is signalled by a long sound signal.
push
sound signal
2x long
button
push
= dynamic*
button
push
= static*
button
sound signal
1x long
27 / 88
push
button
sound signal
1x long
sound signal
1x long