Descargar Imprimir esta página

Aurora AQUA OPTIMA Manual De Usuario página 6

Ocultar thumbs Ver también para AQUA OPTIMA:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
Ensure the water tank is empty and the filter is removed
before starting the descale process.
Descale Procedure:
1. When the descale light is flashing ensure the water tank
is empty and the filter is removed before starting the
descale process.
2. Fill water tank with no less than 3 litres of 1:20 citric acid
solution (1g citric acid powder per 20 ml water).
3. Place jug under dispense nozzle.
4. Press and hold the descale warning symbol for 3 seconds.
5. The descale warning symbol will flash and the appliance
will run a descale process. Caution: Dispense solution
will be hot; around 90°C.
6. When the water tank is empty, refill with 2L of cold water
and press the descale warning symbol again.
7. The appliance will run a cleaning cycle. Caution:
Dispense solution will be hot; around 90°C.
8. The descale warning symbol will turn off once complete.
9. Re-insert the Aqua Optima filter after descale process is
complete.
10. The appliance is now ready to use.
Note:
• To pause the descale process (for example to empty and
replace the jug), press the dispense button. To restart the
descale process, press the dispense button for a second
time.
• Unless the process is run completely the de-scale indicator
will not be reset and the appliance will continue displaying
descale icon.
If the appliance water flow decreases, or scale can be
observed in the dispensed water, a manual descale should
be performed (the descale icon is not illuminated).
Manual Descale Procedure:
1. Ensure the water tank is empty and the filter is removed
before starting the manual descale process.
2. Fill water tank with no less than 3 litres of 1:20 citric acid
solution (1g citric acid powder per 20 ml water).
3. Place jug under dispense nozzle.
4. Select temperature setting of 90C and volume 1000ml
then press the dispense button. Repeat this process 3
times.
5. When the water tank is empty, refill with 2L of cold water.
Select temperature setting of 90C and volume 1000ml
then press the dispense button.
6. Re-insert the Aqua Optima filter after descale process is
complete.
TROUBLESHOOTING
Condition
Machine will not start.
Machine will not dispense.
Descale/Rinse warning symbol is flashing
on screen.
7. The appliance is now ready to use.
7. Installation
The appliance comes with two plug types, one for UK and
one for EU, the correct plug should be used and inserted
into the plug socket.
WARNING: PLEASE DO NOT DISASSEMBLE THIS
APPLIANCE YOURSELF. ELECTRIC ELEMENTS WILL BE
EXPOSED AND THERE IS A RISK OF ELECTROCUTION
POSITIONING OF APPLIANCE
• Do not install this appliance in a very damp or hot place or
near heat source.
• Place the appliance on a flat and even surface.
• Install the appliance in a dry place to avoid damage,
moisture or rust.
• Do not use this appliance outdoors. This appliance is only
suitable for use indoors.
• Do not overhang the power cord and/or water tray off a
table, counter or other surface and avoid contact with
hot surfaces.
• WARNING: DO NOT INSTALL THIS APPLIANCE IN DIRECT
SUNLIGHT.
• Ensure that the ventilation on both sides is never blocked
or covered and ensure a minimum distance >4 inches
(100mm) from the rear wall and right side as shown in the
image.
• WARNING: When positioning the appliance, ensure the
supply cord is not trapped or damaged.
• WARNING: Do not locate multiple portable socket-outlets
or portable power supplies at the rear of the appliance.
Possible cause
Appliance is unplugged.
Appliance requires rinse cycle.
Appliance needs descaling.
5
Solution
Ensure the power cord is inserted in the
appliance and the plug is securely placed
into the socket.
Perform rinsing cycle using the instructions
in section 5.
Perform descale cycle using the
instructions in section 6.
e s
> 4 i n c h
)
(1 0 0 m m

Publicidad

loading

Este manual también es adecuado para:

Auh011