REF.54368
When the colour of new and used fluid is simi-
lar that means the exchange finished.
Stop the engine.
Press Stop.
When the exchange finished, wait 30 minutes
before removing the hoses.
Check if the quantity of coolant fluid is
enough.
If not enough, fill the radiator with more.
Recover
Press Recover.
Start the engine.
When the liquid begins flowing in the red
hose, press "Run".
The machine will recover the used fluid and
will put it in the used liquid tank.
When the recovering is complete, press "Stop".
Warning! While performing this function plea-
se check the temperature.
If the temperature is too high, stop the pro-
cess immediately.
Empty new tank
Connect this tube to the yellow hose.
Put the end of the tube inside a tank.
Press "Empty new tank".