Descargar Imprimir esta página

Panlux SL2700 Instrucciones página 3

Pir sensor 270
Ocultar thumbs Ver también para SL2700:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 5
ENG
INSTRUCTIONS
MODEL:
SL2700/B
SL2700/C
Before using or installing the product, kindly read the instructions and follow safety rules. Installation should
be provided by qualified person or company.
Thank you for choosing the item of company PANLUX s.r.o.
Technical data
Power supply: 230V~50Hz
Input fuse: 6,3A 250VAC
Supply in standby mode: <0,9W
Current: max. 6,3A
Additional load: max. 1000W (incandescent lamp)
max. 300W (fluorescent lamp)
Protection class: II.
IP Protection: IP44
Angle of detection: horizontal – 270°, vertical – 60°
Rotation of sensor head: horizontal - ±45,
vertical – 25°
Reach: max. 12m
Time setting: 10s (±5s) to 4min (±1min) (TIME),
adjustable
Twilight setting: 3-2000lx (LUX), adjustable
Recommended installation height: 2,5m
Terminal block: 4x1,5mm²
Operating temperature: -10°C~50°C
Location: interiors, exteriors
Dimensions: 150x70x95mm
Weight: 237g
Material: plastic ABS
Remarks: relay contact on output
Installation
1
2
95mm
45°
45°
25°
150mm
Notice
Before using, check the product and make sure there is no damage,
otherwise do not use it.
Before any manipulation assure that mains electrical supply is
disconnected.
In case of damage do not repair or disassemble the product.
For the best functional results, move toward the sensor (see to pic. 6).
The incorrect function of the product can be caused by interruption of
electromagnetic field, small temperature difference between moving
object and surroundings, reflection (e.g. strong luminous source).
Before using the grounding point for lamps of I. Class of protection,
the line of lamps must be properly grounded according to valid
standards.
Infringement of any mentioned instruction can cause harm to health
or property.
3
L
N
230V~50Hz
Principle of PIR sensor
PIR sensor receives infra-red waves emitted by objects in reach radius. With movement in the detection area sensor notices
the change and initiates trigger order „Light on" for adjusted time.
Reach setting (sensitivity) – max. 12m
Reach is to be understood as the area traced out by angle of detection and min. to max. available distance from sensor.
Reach can be changed with rotation of sensor head.
Time setting (switch-off delay) – TIME (10s (±5s) to 4min (±1min))
The countdown of adjusted time begins after last detected movement. We recommend setting the function on minimum
during functional test.
Twilight setting (response threshold) – LUX (3-2000lx)
We recommend setting the function on maximum during test.
Stated information may differ according to position and installation height.
Position marked - or  applies to minimum and position marked
If the product is mechanically damaged or connected unprofessionally, guarantee cannot be allowed.
4
5
L
SL2700
PIR sensor 270°
or
applies to maximum.
+
6
270°
60°
12m
2,5m
All right reserved.
Technical data can be changed without previous notice.
UM_SL2700_121105

Publicidad

loading

Productos relacionados para Panlux SL2700

Este manual también es adecuado para:

Sl2700/bSl2700/c