4.2 Check and filling oil
NOTE: The machine is delivered without oil; do not attempt to start up the
machine without adding oil first!
Ensure that the generator is on a perfectly leveled surface to avoid mistakes in the
oil level.
Remove the oil filling cap and pour oil in the hole until the maximum level shown in
the figure below is reached.
Oil capacity to the correct level according to the model is:
 RODAS 3800W model
 FEROE 4600W model
Use good quality SAE10W30 or SAE10W40 synthetic 4-stroke motor oil.
Recommended oil classification: API "SJ" (USA) or ACEA "A3" (EUROPE) or
more current (See container specifications).
NOTE: Consider that the engine consumes some oil during running. Check
the oil level before each use and refill if the level has diminished.
NOTE: Never use old, dirty or bad oils. Do not use oil if you don't know its
grade and quality. Do not mix different types of oils.
0.6L approximatelly
1.0L approximatelly