Remove
return
rollers.
Pry roller
supports
up and out of
cap. Remove
set screw
from each
column
beneath
cap
(see Figure
28).
Cap
RollerJ
Figure 28 - Loosen Cap
•
Remove
the depth
control
knob (see
Figure
16, page
8).
Lift cap slightly
and remove
the side cover.
•
Disengage
the spring
from the latch so that the pulleys
will turn freely
(see
Figure
29).
Drive Belt
Fan Belt
Figure 29 - Right Side of Planer with
Side Cover Removed
•
Remove
fan belt by walking
the belt (one groove
at a time)
from
both pulleys
alternately.
Pull the belt while turning
the pulleys
at the same
time. Repeat
with drive belt.
•
Replace
with new belts. Walk
the belt onto the pulleys
in
the reverse
manner
as when removing
the belts.
•
Make sure the belt is evenly
seated
on all grooves
on
both pulleys.
•
Replace
right
side cover and knob. Secure
cap with set
screws.
Replace
sensor
and secure
in position.
Secure
display
cover
in position.
Replace
handle
and secure
with plug and socket
head
bolt.
CALIBRATING
THE
THICKNESS
PRESET
GAUGE
Refer to Figure
30.
Loosen
hex nut (Key No. 64). Carefully
turn gauge
stop (Key
No. 65) to desired
position.
Gauge
stop has 16TPI thread,
one full turn of gauge
stop will move
the rollercase
0.062"
rel-
ative to the thickness
preset
gauge.
Secure
stop
in position
by
tightening
hex nut.
12