1-4. INSTALLATION DIAGRAM
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1)
Installation plate
Attachment screws for the installation
(2)
plate
4 × 25 mm
(3)
Wireless remote controller
(4)
Felt tape (For left or left-rear piping)
(5)
Remote controller holder
Screws for the remote controller holder
(6)
3.5 × 16 mm (Black)
(7)
Battery (AAA) for (3)
(8)
FIELD-SUPPLIED PARTS
(A)
Indoor/outdoor unit connecting wire*1
(B)
Extension pipe
(C)
Wall hole sleeve
(D)
Wall hole cover
(E)
Pipe attachment strap
(F)
Screw for (E) 4 × 20 mm
(G)
Piping tape
(H)
Putty
Drain hose
(I)
(or soft PVC hose, 19/32 in. [15 mm]
inner diameter or hard PVC pipe VP16)
(J)
Refrigerant oil
(K)
Power supply cord*1
<FS06/09/12>
4 in. (100 mm) or more when front
*2
and sides of unit are clear
When any 2 sides of left, right and
*3
rear of unit are clear
31-1/2
5-15/16
19-11/16
Air inlet
1-9/16
Air outlet
×
2-3/8
13/16 slot
Units should be installed by licensed contractor according to local code requirements.
Note:
• The dimensions indicated in the arrows (
show the required space to guarantee performance of
the air conditioner. Install the outdoor unit where the
maximum possible space can be provided, consider-
ing later relocation, services, or repairs.
power usage may fall about 10% at the place where
short cycle is likely occur due to poor ventilation.
Installing the air outlet guide (optional) can improve
performances.
• If air from the outlet blows against the wall, it may
cause stains on the wall.
Drain piping for outdoor unit
Install the unit horizontally.
Do not use drain socket in cold regions. Drain may freeze and make the fan stop.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unit and/or the grounds from being wet by drain
water or damaged by frozen drain water.
1
5
1
1
1
2
2
2
1
1
1
1
2 to 5
2 to 5
1
1
1
Note:
Place indoor/outdoor unit connecting wire (A)
*1
1
and power supply cord (K) at least 3 ft. (1 m)
1
away from the TV antenna wire.
Unit: inch
800
150
500
Air inlet
Air outlet
2-10 × 21 slot
) above
<FS15/18>
20 in. (500 mm) or more when front
*2
and sides of unit are clear
When any 2 sides of left, right
*3
and rear of unit are clear
Unit: mm
6-7/8
40
2-3/8 × 13/16 slot
Do not take in the outlet air
discharged by other units directly.
Use the wall hole sleeve (C) to prevent
indoor/outdoor connecting wire (A) from
contacting metal parts in the wall and to
protect the wiring from rodents.
Indoor unit
Wall hole
sleeve (C)
Cut off the
extra length.
After the leak test, apply insulating material
tightly so that there is no gap.
When the piping is to be attached to a wall
comprised of tin plate or metal netting, use
chemically treated wooden piece 25/32 in.
(20 mm) or thicker between the wall and the
piping, or wrap insulation vinyl tape 7 to 8
turns around the piping.
To use existing piping, perform COOL opera-
tion for 30 minutes and pump down before
removing the old air conditioner. Remake
refrigerant.
Unit: inch
33-1/16
19-11/16
Air inlet
Air outlet
1-9/16
2-10 × 21 slot
Wall hole cover (D)
Seal the wall hole
gap with putty (H).
Attach the pipe
to wall with pipe at-
tachment strap (E).
Pipe attachment
strap (E)
Attachment screw (F)
(K)
(I)
(A)
(B)
Unit: mm
840
175
500
Air inlet
Air outlet
40