PROTECTIVE FEATURES OF THE INVERTER
Your inverter monitors the following potentially hazardous conditions:
OVER TEMPERATURE PROTECTION – If the temperature inside the inverter is too high, the
unit will automatically shut down. Allow the unit to cool for at least 15 minutes before restarting
after a heat-related shutdown. Unplug unit while cooling.
LOW BATTERY VOLTAGE PROTECTION - This condition is not harmful to the inverter but
could damage the power source. The inverter automatically shuts down when input voltage drops
to 56 volts. When the condition is corrected, the unit may be restarted.
OVER VOLTAGE PROTECTION – The inverter will automatically shut down when the input
voltage exceeds 85 volts DC.
OVERLOAD PROTECTION – The inverter will automatically shut down when the continuous
draw exceeds rated watts.
SHORT CIRCUIT PROTECTION – The inverter will shut down. Remove the short circuit and
restart the inverter after 5 minutes.
5