28
Problem
O
.Automatic.mode.
skipped,.appliance.
goes.straight.to..
N
.Manual.mode.
The.quality.of.
the.crema.has.
deteriorated.
Brewing.unit.cannot.
be.securely.closed.
Water.dripping.from.
the.brewing.unit.
Water.on.the.surface.
under.the.cup.stand.
Service.T.DISC.is.
damaged.or.lost.
More.Customer.Service.information.is.available.online.at.www.tassimo.com
Robert.Bosch.Hausgeräte.GmbH
01_TAS 40_Heft1.indb 28
Possible!cause
The.barcode.could.not.be.
detected.
The.drink.outlet.is.clogged.or.
dirty.
Piercing.unit./.T.DISC.holder.
is.not.properly.inserted.
The.T.DISC.is.not.inserted.
properly.
The.brewing.unit.is.not.
properly.closed.
The.T.DISC.is.damaged.or.
leaky.
The.piercing.unit.is.either.
not.inserted.or.not.inserted.
properly.
Water.from.condensation.
The.Service.T.DISC.must.
always.be.used.for.cleaning.
and.descaling.processes.
Solution
Clean.the.bar.code.reading.
window..
Use.another.T.DISC.
You.can.still.prepare.the.drink.
by.holding.down.the.start / stop.
button.
Remove.the.drink.outlet.
from.the.brewing.unit.and.
detach.the.piercing.unit..
After.cleaning.everything.
thoroughly,.reassemble.the.
parts.and.replace.them.in.the.
brewing.unit.
Insert.the.T.DISC.holder.and.
piercing.unit.properly.
Re-insert.the.T.DISC.and.
make.sure.it.is.properly.
positioned.
Push.the.clamp.down.firmly.
until.it.audibly.clicks.into.
place.
Stop.the.brewing.process,.
remove.the.T.DISC.and.clean.
the.brewing.unit.
Check.to.ensure.that.the.
piercing.unit.is.inserted.
properly.
Condensation.may.occur.and.
is.not.a.fault..Remove.it.by.
wiping.with.a.cloth.
Look.for.the.Service.T.DISC.
in.the.storage.compartment.at.
the.back.of.the.appliance.
The.Service.T.DISC.can.be.
obtained.from.the.Bosch.
customer.service.department.
(article.no..611632,.for.contact.
details,.see.page.150).
en
09.04.2011 12:48:12