Wallplate installation
1. Separate wallplate from thermostat.
2. Mount wallplate as shown below.
Back of
Thermostat
Drill 3/16" holes for drywall. Drill 7/32" holes for plaster.
Wall anchors
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube,
do not place the old control in the trash.
69-2815EFS—07
Wire hole
Wallplate
LEVEL
HERE
C
K
Rc
R
2
Wallplate
Mounting screws
W-
O/B
Y
G
W2-
Aux/E
Y2
L
M34819