7-5
Setting Parameters
D) Selection of the unit of measurement for run-out,
in mm or inches.
Default value: mm.
E) Limit (threshold) for wheel peak-to-peak radial Run-
out. Default value: 1.5 mm.
F) Scanning for wheel information detection is always
performed during the first run. Should it be necessary
to carry out more than one run for the same wheel,
this function allows disabling the laser scanners
during any further runs after the first, so as to
optimise operating time.
Set to "0" to scan automatically and only upon first
run, just after wheel clamping.
Set to "1" to scan automatically upon every single
wheel run (Default value).
G) Limit (threshold) for rim lateral/radial Run-out of 1st
Harmonic. Default value: 0.7 mm.
H) Limit (threshold) for rim peak-to-peak lateral/radial
Run-out. Default value: 1 mm.
I) Enable/Disable view for the analysis of the three
harmonics of the Run-out.