(B) Nipple has to be
centered into the LP
tank valve
5. Hold regulator, insert nipple (B) into LP
tank valve. Hand tighten coupling nut,
holding regulator in a straight line (C) with
LP tank valve so as not to cross thread the
connection.
6. Turn the coupling nut clockwise to tighten
to a full solid stop. The regulator will seal
on the back-check feature in LP tank valve,
resulting in some resistance. An additional
one-half to three quarters turn is required
to complete connection. Tighten by hand
only – do not use tools.
NOTE: If you cannot complete connection,
disconnect regulator and repeat steps 5
and 6. If you are still unable to complete the
connection, do not use this regulator!
• Do not insert any foreign objects into the
valve outlet. You may damage the valve and
cause a leak. Leaking propane may result
in explosion, fire, severe personal injury, or
death.
• Never attempt to attach this appliance
to the self-contained LP gas system of a
camper or trailer or motor home.
Appliance must be leak checked outdoors
in well-ventilated area, away from ignition
sources such as gas fired or electrical
appliances. During leak test, keep appliance
away from open flames or sparks.
NOTE:
represents off.
Leak Testing
1. Turn all control knob(s) to OFF.
2. Be sure regulator is tightly connected to LP
tank.
8
(C) Hold coupling
nut and regulator
as shown for proper
connection to LP
tank valve
WARNING
3. Slowly open LP tank valve by turning hand
wheel counter clockwise. If you hear a
rushing sound, turn gas off immediately.
There is a major leak at the connection.
Correct the leak before proceeding.
4. Brush 50/50 soap and water solution onto
indicated connections shown.
5. If "growing" bubbles
appear, there is a leak. Close LP tank valve
immediately and retighten connections.
If leaks cannot be stopped, do not try to
repair. Call for replacement parts. Order
new parts by giving the serial number,
model number and name of items needed
to the Service Center.
6. Always close LP tank valve after
performing tank leak test by turning hand
wheel clockwise.
• Do not use appliance until leak checked.
• If you cannot stop a gas leak, immediately
close LP tank valve and call LP gas
supplier or your fire department!
Hose Check
• Before each use, check to see if hoses
are cut or worn. Replace damaged hose
assembly before using appliance. Use
only valve/hose/regulator specified by
manufacturer. See product sheet for hose
and regulator information.
Valve Check
Visually inspect the valve to burner assembly
to ensure the orifice is properly located in the
burner. As shown.
WARNING