• Damage may occur if the DC cable supply
is not appropriately sized. This will cause
low voltage. The table below provides rec-
ommended cable sizing from battery to
appliance:
Cable cross
12 V
section in
maximum
mm² (AWG)
cable length
in m (ft)
2.5 (13)
2.5 (8.2)
4
(11)
4
6
(10)
6
10
(7)
10
• When using the appliance ensure the cir-
cuit being used has a fuse or circuit break-
er. The recommended size for DC 12 V is
10 A, DC 24 V is 5 A.
8
24 V
maximum
cable length
in m (ft)
5 (16.4)
(13.1)
8 (26.2)
(19.6)
12 (39.3)
(32.8)
20 (65.6)
• Make sure that the voltage data on the
type plate matches the existing power sup-
ply. Incorrect mains supply can damage the
appliance. This is especially important for
AC generators that can generate voltage
spikes.
• If your appliance is plugged in to a DC ve-
hicle socket, ensure that you disconnect
from power when the vehicle is not in use
to prevent battery drainage.
• Never disconnect the appliance by pulling
the cable instead of the plug.