DISPOSAL
At the end of its useful life, you have to scrap and dispose of this
product by taking it to a local differentiated waste collection center in
conformity to law.
Before scrapping, check the serial number plate on the machine: if
it has the symbol
, it means that disposal is regulated by EU Direc-
tive 2003/96 (Waste Electrical and Electronic Equipment, WAEE).
OBSERVED FAULTS, POSSIBLE CAUSES AND REMEDIES
OBSERVED FAULT
• The fan doesn't start
• The fan starts but there is not enough heat
• The space heaters stops and the light "c" comes on • Safety thermostat intervenes
waste collection system and follow its instructions.
riously harm the environment and health and is subject to administra-
tive penalties.
CAUSE
• No electrical current
• Winding of motor burnt or interrupted
• Motor bearings blocked
• Wrong setting of safety device
• Defective control device
11
The user must inquire about the local electrical and electronic
Illegal disposal of this product with normal domestic waste can se-
• Check mains, it should be:
•
EK 3 A: 230V ~ 50Hz
•
EK 9 A - EK 15 A: 400V 3 ~ 50Hz
• Check proper positioning and functioning of
•
switch
• Replace motor
• Replace bearings
• Check correct setting of heater control (make sure
•
selected temperature is higher than room
•
temperature)
• Replace control device
• Identify the problem that caused the overheating.
•
In models EK 3 A and EK 9 A, the reset button is
•
placed on the machine cover, in models EK 15 A, it
•
is placed at the back.
GB
REMEDY