Descargar Imprimir esta página

K-Jump Health SC 1493 Manual De Instrucciones página 5

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 3
Classic waterproof clinical thermometer
SC 1493 with flexible measuring point
Special features
The SC 1493 is a waterproof, digital fever thermometer with a flexible measuring tip. It displays
the highest temperature within 10 seconds. It has a memory function to store the last measured
value. A fever alarm beeps when the temperature measured exceeds 37.5°.
Safety information
♦ The SC 1493 is suitable only for measuring human body temperatures.
♦The thermometer contains small parts (batteries, etc) which could be swallowed by small
children. Please keep the thermometer and its batteries out of the reach of small children. If the
battery or other parts are swallowed you should seek medical help immediately.
♦The enclosed batteries may not be recharged or reactivated by other methods, may not be
dismantled, thrown into fires or short-circuited.
♦Protect the SC 1493 from direct sunshine and temperatures above 50°C.
♦Never drop the SC 1493, do not bend or open it (with the exception of the battery
compartment for battery replacement).
Microbial contamination
Because a hundred percent disinfection is not possible under conditions at home, it is urgently
recommended that every patient should use their own fever thermometer.
Operating manual
Press the 0/I button to switch on. A short signal tone shows that the device is in the "switched
on" mode. A segment test takes place simultaneously (checks all display segments).
After this, if the temperature measured by the temperature sensor is less than 32°C, the display
shows an "L" and "°C". After around one second, the "°C" starts to blink. The „L" stands for low
(less than 32°C). The current temperature is continuously displayed during measurement, and
the "°C" blinks during the entire measurement time. The measurement is completed after
around 10 seconds and "°C" stops blinking. After the measurement is completed, the
temperature value measured remains in the display
until the SC 1493 is switched off. To turn the device off after use, press the 0/I button briefly.
The signal tone will again be sounded. If the device is not switched off, a signal tone is sounded
after around 3 minutes and the device then switches off automatically.
Fever alarm
If the temperature measured is 37.5°C or higher, the fever alarm beeps (short double beeps for
about 4 seconds) and the LC display flashes.
Display of last measured value
If you keep the 0/I button pressed for longer than three seconds, the last measured value will be
shown in the display. As soon as you release the 0/I button, the thermometer returns to
measurement mode.
Measured value deviation
The measured temperatures will always deviate, depending on the measurement location. This
is normal, and caused by deviations in temperature distribution on the human body. You could,
for example, measure a rectal temperature of 36.5°C, an oral temperature of 36.0°C and an
underarm value of 35.5°C.
Measurement locations
In the mouth (oral)
Small
temperature
variations
in
the
mouth
between
measurements are normal. These are caused by varying
temperature distribution within the mouth. Try to place the
thermometer in one of the two heat pockets under the tongue,
to the left and right of the tongue root. The measurement
sensor must have good contact with the tissue. The subject
should close the mouth and breathe normally through the nose
so that the measured result is not affected by breathed air.
Measuring period: approx. 10 seconds.
In the anus (rectal)
This is the most accurate method. It is particularly suitable for infants and small children.
Carefully guide the tip of the thermometer approximately 1 cm into the anus. Measuring period:
approx. 10 seconds.
Under the arm (axillary)
From a medical viewpoint this type of measurement leads to inaccurate values. It is
therefore unsuitable for carrying out exact measurements.
Changing the battery
As soon as the
symbol appears in the display, the battery has run out and requires
replacement. Always replace the discharged battery with one of the same type (LR 41 or AG3).
To do this, proceed as follows:
Pull the cover off the battery compartment. The battery can now be accessed.
Remove the used battery with the help of a pointed object (pincers, small screwdriver etc.) and
put the new battery in. Please make sure it is the right way round.
Measurement checks
Checking the accuracy of the SC 1493 is not necessary in most cases.
Cleaning and disinfection
Please only use an alcohol pad. Alcohol pads can be purchased from any dispensing chemist.
We recommend the use of Mucocit-F2000 or HelipurHplus to disinfect the thermometer
when it is being used in medical facilities. Both are effective against all hospital-typical
pathogens and can be purchased from any dispensing chemist.
Guarantee
We give a guarantee period of 2 years from the date of purchase. We guarantee perfect design
of this article. We will rectify all material or manufacturing errors during the guarantee period. If,
contrary to expectations, defects are found, please send the device back to the importer. Please
enclose the proof of purchase and a description of the defect so that the problem can be
rectified as soon as possible. The guarantee excludes damages caused by improper handling,
related to the battery or to the packaging.
Disposal note
The disposal of batteries is regulated. Spent batteries are collected at collection points
provided by battery dealers and the communities. Dispose of the thermometer monitor as
prescribed. i.e., at a collection point for electrical scrap. Dispose of the thermometer
monitor as prescribed. i.e., at a collection point for electrical scrap.
Specifications
Type:
maximum thermometer
Measuring range:
32.0°C to 43.9°C
Temperature below 32.0°C: display "L" for low.
Temperature above 43.9°C: display "H" for high.
Measurement accuracy:
0.1°C between 35.5°C and 42.0°C (0.2°C other range) at a
surrounding temperature of 18°C to 28°C.
Display:
liquid-crystal (LCD display).
Battery type:
1 no.: LR 41 or AG3.
Battery display:
The symbol
shows when the battery is discharged.
Storage temperature:
0°C to 50°C
Explanation of symbols
K-jump Health Co., Ltd.
No.56, Wu Kung 5th Rd.
New Taipei Industrial Park
New Taipei City, 24890 Taiwan
Polygreen Germany GmbH
Ruhlsdorfer Str. 95
14532 Stahnsdorf, Germany
Importer
SCALA Electronic GmbH
Ruhlsdorfer Str. 95
14532 Stahnsdorf, Germany
Rev. 04/03/2021/GB,F

Publicidad