Starting the configuration:
Set the 3 switches to configuration position 0/P
Switch on the power supply of the device
SWITCH / LED
OPERATION / RESULT
1.
The LED CONF is blinking
Adjust Potentiometer P1 from
the position 0/P to the needed
Value
2.
During the rotation, the led
ENA lapse by every Step
(1), (4)
(check with this visualization
the corrected value)
3.
System resting in
Configuration-Mode Waiting
for input P2
(2)
4.
The LED CONF is still blinking
E) SEGNALAZIONI - STATUS INDICATORS - INDICATEURS - STATUSANZEIGEN - INDICADORES DE ESTADO
LED
IN2
IN1
K2
K1
ENA
CONF
ON
FAULT
F) SCHEMI DI CONNESSIONE – WIRING DIAGRAMS – SCHÉMAS ÉLECTRIQUES – SCHALTPLÄNE – ESQUEMAS DE CONEXIÓN
SV MR0 – Manual mode
SV MR0 U – Manual mode
Consultare il manuale per il dettaglio dei cablaggi nei diversi modi di funzionamento.
Refer to the manual for details of wiring in the different modes of operation.
Consultez le manuel pour savoir comment s'effectue le câblage dans les différents modes de fonctionnement.
Einzelheiten zur Verdrahtung in den verschiedenen Betriebsarten finden Sie im Handbuch.
Consulte el manual para los detalles de cableado en los diferentes modos de operación.
R
R S.p.A. Via Carcano 32, 10153 Torino Italia - Tel. +39 0112482215 r.a. Fax +39 011859867 - Internet: www.reersafety.com - e-mail:
EE
SV MR0 - SV MR0 U
SWITCH / LED
(3)
(1)
COLOUR
NAME
YELLOW
Input Sensor IN2
YELLOW
Input Sensor IN1
GREEN
Indicator Relay K2
GREEN
Indicator Relay K1
YELLOW
Indicator Enable
BLUE
Indicator Configuration
GREEN
Power Supply Indicator
RED
Fault Indicator
OPERATION / RESULT
Adjust Potentiometer P2 From
the position 0/P to the needed
Value
1.
During the rotation, the led
ENA lapse by every Step.
2.
System resting in
Configuration-Mode Waiting
for Input P3
3.
The led CONF is still blinking
ON, when a high signal at the input IN2 was detected.
ON, when a high signal at the input IN1 was detected.
ON when the safety output relay K2 is switched on.
ON, when the safety output relay K1 is switched on.
ON when the Enable inputs are logical on. In configuration mode this LED blinks rotating the
potentiometers (one blink for each step). In clear status (waiting for a restart command) this led blinks.
ON when device in configuration mode. Blinking when switches are in P position.
ON, when the safety module is powered.
ON, when an internal fault is detected.
Indicator Fault is flashing, when an external fault (i.e. the sensor-test) is detected.
info@reer.it
QUICK START SAFETY GUIDE
SWITCH / LED
OPERATION / RESULT
Adjust Potentiometer P3 From
the position P to the needed
Value
1.
During the rotation, the led
ENA lapse by every Step
2.
Led CONF becomes fixed.
(3)
Wait until led CONF is blinking
twice (memorization)
Turn OFF the power
(1)
BEHAVIOUR
SV MR0 – Automatic mode
SV MR0 U – Automatic mode
2/2