• Make sure that the water condensation of the unit can drain without obstacles.
• Do not operate the air conditioner with wet hands. lt can cause an electric shock.
• Do not use the device far any purpose other than the intended use.
• Do not climb or place objects on the outdoor unit.
• Do not allow the air conditioner to operate far long periods of time with the doors or windows open, or if
the humidity is very high.
the plug. Dirty plugs can cause fire or electric shock.
• Do not pull the power cord to unplug the unit. Hold the plug firmly and remove it from the power outlet.
Pulling the cable directly can damage it, which can cause a fire or an electric shock.
• Do not modify the length of the power cord or use an extension cord to power the unit.
• Do not share the power outlet with other devices. An inadequate or insufficient power supply can cause a
fire or an electric shock.
• The product must be properly grounded at the time of installation, otherwise an electric shock may occur.
• Far all electrical maneuvers, follow ali local and national wiring regulations, regulations and lnstallation
Manual. Connect the wires firmly and secure them firmly to prevent externa! forces from damaging the
terminal. lncorrect electrical connections can overheat and cause a fire, and can also cause a discharge.
AII electrical connections must be made in accordance with the Electrical Connections Diagram located
on the panels of the indoor and outdoor units.
• AII wiring must be properly arranged to ensure that the control board cover can be closed properly. lf the
control board cover is not closed properly, it can cause corrosion and cause the connection points in the
terminal to become hot, catch fire or cause an electric shock.
• lf you connect the power to the fixed wiring, you must incorporate a disconnection device of all the pales
that has at least 3 mm of free space towards all the pales, and with a leakage current that can exceed 1 O
mA, having the device residual current (RCD) a nominal residual operating current that does not exceed 30
mA, and the disconnection must be included in the fixed wiring in accordance with established standards.
TAKE NOTE OF THE FUSE SPECIFIATIONS
The
air
conditioning
current
protection.
lndoor unit: T3.15AL / 250VAC, T5AL / 250VAC, T3.15A / 250VAC, T5A / 250VAC, etc.
Outdoor unit: T20A / 250VAC (units with Btu / h <= 18000), T30A / 250VAC (units with Btu / h> 18000)
NOTE: For units with R-32 refrigerant, only the explosion-proof ceramic fuse can be used. .
26
CAUTION
• Turn off the air conditioner and turn off the power if you are not going to
use it far a long time.
• Turn off and unplug the unit during storms.
ELECTRICAL WARNINGS
• Use only the specified power cord. lf the power cord is damaged, it must be
replaced by the manufacturer or its service agent or a duly qualified person,
in arder to avoid risks.
• Keep the power plug clean. Remove dust or dirt that collects in or around
circuit
board
(PCB)
Fuse
specifications
are
1 PRECAUTIONS AND WARNINGS
is
designed
with
a
printed
on
the
circuit
Split 1x1
AROMA 2E
fuse
to
provide
over­
board,
such
as: