Ermenrich Ping RD40 Radiation Detector
EN
Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the device only as
specified in the user manual.
The kit includes: radiation detector, Type-C USB cable, user manual, and warranty.
Charging the device
This device uses a built-in rechargeable lithium battery. Connect the USB cable (included) to the device and the DC adapter (not included) via a
USB plug and connect it to the AC power supply to charge the device.
!
The battery needs to be recharged once every 12 months.
Getting started
Press (5) and hold it for 3s in order to turn the device on/off. The device enters Radiation measurement mode by default. To switch to the main
menu, press (5).
!
When the device is locked, it is not possible to turn the device off. Select Schedule (Timed measurement) and click Stop timer
(Stop the timer) to turn the timer off.
Usage
Radiation measurement
Select Measure (Radiation measurement) in the main menu to check the real-time, average/cumulative dose rates, and total
measurement time.
Timed measurement
Select Schedule (Timed measurement) to set the delay time. You can set the delay value between 00 and 99h and a timer value between
00 and 999h. Click Start timer (Start the timer). The device starts counting down. After the Start delay countdown is completed, the real-
time dose rate, average dose rate, total measurement time, and cumulative dose rate are reset at the same time. The device starts to
Measure the real-time dose and cumulative dose rate. After the countdown is finished and the measurement is completed, the device
automatically saves the measured data in the history record.
The Start delay (Start the delay time) setting is the countdown to starting the measurement. It can be set in hours, minutes, and seconds.
Press Start timer (Start the timer) to enter countdown mode. The measurement starts after the countdown is finished.
History records
A history record is automatically saved at the end of each measurement. When 10 history Records have been saved, the newly saved
history record will overwrite the oldest one. Select Records (History records) to view the history records.
Data deletion
To delete the current data and history data, select Delete (Data deletion) menu. Select Delete Current Data (Current data deletion) to
delete the average dose rate and total measurement time. Select Delete History Data (History data deletion) to delete the history records.
Alarm value setting
Select Alarm (Alarm setting) to set the dose rate and total dose high alarm values using (4) or (6). The device will emit an audible and
visible alarm signal when the radiation concentration exceeds the set alarm values.
Real-time dose rate limit value setting range: 0.1-999µSv.
Total dose rate limit value setting range: 1-9999µSv.
Unit setting
Select Unit (Unit of measurement setting) in the main menu. Press (4) or (6) to switch between µSv and µGy.
Sound setting
Select Sound (Audio setting) to set the alarm volume (0 to 9 levels), the number of alarms (0 to 10 times), and the particles Sound (on/
off). If the particles sound is on, the device will emit sound when the sensor detects ion particles.
Time setting
Select Clock (Time setting) to set the date and current time.
Date setting: Year > Month > Day
Time setting: Hours > Minutes > Seconds
Hibernation setting
Select Sleep (Hibernation setting) to set the screen off time (in minutes), auto power-off time (in hours), and screen brightness level.
3