CoolAir
5.3.4 Connecting the condenser unit to the evaporator unit
Caution
Avoid narrow radii during bending. Use a suitable round object as a
bending aid. If the radius is too narrow, the refrigerant line will be kinked
and the air conditioner would not be ready for operation.
Caution
Before fastening the connection couplings, make sure that the sealing
and thread faces are absolutely clean. Any contamination will result in a
malfunction of the air conditioner.
➤ At the rear panel of the lorry, bend the connection line down vertically
➤ Install the connection line for the condenser unit and insert it in the
Caution
To screw and tighten the coupling halves, always use an open-ended
spanner to firmly hold the fixed coupling half in position.
Make sure that the coupling half with the thin capillary tube is not twisted
or kinked.
Caution
The tube couplings are single couplings! The couplings must not be
removed once they are connected.
➤ Join the rear coupling halves (thin refrigerant line) and use an
➤ Join the front coupling halves (thick refrigerant line) and use an
➤ Insert the protective sheath in the holder, under the coupling.
➤ Use the supplied pipe clip to fasten the refrigerant line to the holder in
a
a
with a radius of approx. 50 mm.
condenser unit.
a
I
a
open-ended spanner to hand-tighten the connection + 1/4 turn
(see Fig. 9 on page 6).
open-ended spanner to hand-tighten the connection + 1/4 turn
(see Fig. 10 on page 6).
the condenser unit (see Fig. 11 on page 7).
Installation
39