SPECIFICATIONS
System Voltage
Turn ON Voltage
Turn OFF Voltage
Turn ON Delay
Turn OFF Delay
Instant OFF Voltage
Max. Continuous Current
Max. Inrush Current
RECOMMENDED FUSES AND CABLING
Suitably sized wire and fuses for the connected loads should be used.
REDARC recommend using MIDI fuses along with a quality fuse holder to
match (cables not included).
Part Numbers
FK40
FK60
INSTALLATION INSTRUCTIONS
1. Mount the SBI12-BLD securely in a convenient location near the auxiliary
battery bank. Do not mount in direct engine heat.
2. Install in the order described below:
ƒ Ground connection. Connect the SBI12-BLD ground terminal to the BMS
Load Disconnect terminal. NOTE: A good connection will ensure correct
switching voltage.
ƒ Select correct circuit Breaker/Fuse sizes and install at battery end of the
positive cable.
ƒ LED Connections (optional). Connect a wire from the Blue wire of the
SBI12-BLD to the positive end of an indicator LED (15 mA limited current
draw) or LED/resistor combination.
ƒ Install and operate in conjunction with the BMS user manual.
FAULT INDICATION
NOTE: The LED will be on when the SBI12-BLD is active (on).
Should a fault occur, the SBI12-BLD is set to notify the operator of the fault.
The LED will flash repeatedly with the following sequences:
CODE 1
2 Flashes
Over-Voltage
CODE 2
3 Flashes
Voltage Drop or Excessive Current Draw Fault
Fault Code 1:
If the battery connected to the SBI12-BLD should rise above 16.5 V, the
Smart Start
will:
®
ƒ Disconnect, to prevent the source of over-voltage reaching the load.
ƒ Flash the LED 2 times for 20 seconds, then reassess the fault condition,
continuing until the fault is cleared.
12 V Nominal
10.2 V
10.0 V
5 seconds
10 seconds
9.0 V
100 Amps
400 Amps
40 A Fuse Kit
60 A Fuse Kit
Standby Current
Operating Current
Dimensions
Weight
Warranty
Standards
Main Stud Torque
Voltages Specified are ±100 mV
MIDI Fuse with Holder
 CAUTION: Over discharge risk. Ensure that the Turn OFF Level set
on the BMS are suitable for the specifications provided by the battery
manufacturer.
NOTICE: It is normal for the LED to stay ON whenever the auxiliary
battery is in a condition suitable for running loads.
Fault Code 2:
If the SBI12-BLD detects a voltage drop across its contacts of greater than
1 V for more than 30 seconds then the unit will:
ƒ Immediately protect itself and the load by disconnecting the load and;
ƒ Flash the LED 3 times for 20 seconds, then reassess the presence of a
fault, continuing until the fault is cleared.
<5 mA
<0.1 A
75 × 70 × 80 mm (2.95" × 2.75" × 3.15")
200 g (0.4 lbs)
2 years
CE, C-Tick, AS/NZS CISPR11:2004
5 – 6.2 Nm
Fuse Assembly