Layout and function
3.1
Display
The ServiceJunior is screwed into an existing system and measures the
current pressure value. The current pressure (ACTUAL) is shown on the
display. The measured value is shown in the actual value display with
the appropriate unit. The MIN, MAX or FS value is shown in the lower
area of the display.
Display
Bar graph
Actual value
MIN/MAX
FS
Units
12
Description
Displays the current pressure in graphical form.
Displays pressure peaks in the form of a pixel (line).
The display is updated at an interval of 50 ms (20
measurements/s).
Displays the actual pressure.
The display is updated at an interval of 300 ms (3
displays/s).
Displays the MIN, MAX or FS value, depending on
the setting.
The display is updated at an interval of 300 ms (3
displays/s).
Full scale value (e.g. 600 bar).
Displays the set unit.
V1.0/01/20