II. USAGE:
1. Assembling the steam cleaner: Choose the required accessories and
connect them to the steam cleaner.
2. Methods of filling water and caution: Only use clean drinking water. Never
use detergent or other additives in the tank.
3. Filling water into the steam cleaner: To open the safety valve, turn it anti-
clockwise. Note: The safety valve cannot be opened when there is steam in
the boiler; make sure to release all steam before opening it. Use the
provided funnel to fill water into the tank. The capacity is 1000ml. Once the
water is filled, turn the safety valve clockwise to close it securely.
4. Operation:
4.1 Starting the appliance and cautions:
- Connecting power supply: Ensure the input voltage matches the voltage
indicated on the appliance label. Close the heating switch before plugging in
the appliance.
- Plug the appliance: Push down the heating switch to turn on the appliance.
The heating power switch indicator will light up - the heater will start working.
- Ready for use: Once the pressure indicator lights up (indicator 5), it means
the steam has reached the set pressure and temperature - the appliance is
ready for use.
- Cleaning: Before proceeding with cleaning, perform a trial test in a
concealed area using an object that can withstand high temperature and
humidity.
- Open the child security lock.
- Activate steam release: Push the steam release switch.
- Steam cleaning: Spray steam for cleaning purposes.
When the volume of steam decreases and the buzzer sounds, this means
there is a shortage of water - add more water into the boiler.
4.2 Caution during cleaning:
! To prevent electric shock, do not clean electrical appliances.
! To prevent scalding, do not clean chemical fibres or silk.
! When cleaning windows during winter, keep the jet nozzle 30cm away from
the glass at first - this preheats the glass and prevents it from cracking.
4.3 Fill water for continuous use
! Before opening the safety valve and filling the appliance with water, ensure
there is no steam left and the pressure in the boiler is released. Note: The
safety valve cannot open when there is pressure in the boiler – this is a
special safety design. Always prioritise safety when using this appliance.
7