Ermenrich Ping RD20 Radiation Detector
EN
Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the device only as
specified in the user manual.
The kit includes: radiation detector, Type-C USB cable, user manual, and warranty.
Getting started
Press (5) and hold it for 3s to turn the device on/off. The device enters dose rate measurement mode by default.
Charging the device
This device uses a built-in rechargeable lithium battery. Connect the USB cable (included) to the device and the DC adapter (not included)
via a USB plug and connect it to the AC power supply to charge the battery. A USB connection message will appear. The LED indicator is
green during charging.
!
The battery needs to be recharged once every 12 months.
Usage
Press (3) to switch between the following modes:
1) DOSE RATE: instantaneous dose rate
2) DOSE: accumulated dose rate taken for a certain period of time
3) AVR: average dose rate taken for a certain period of time
4) MAX: maximum dose rate registered from the moment the radiation detector was turned on
During the dose rate measurement, LED indicator (2) will be blinking in green. All of the data is reset after the device is turned off.
Alarm settings
To go to the radiation detector alarm settings, press (3) and hold it for 3s, then press (5). The lock symbol will disappear.
Instantaneous dose rate alarm
Press (3) and go through the menus to select DOSE RATE Alarm screen.
Press (5) three times to select the dose rate alarm setting. The alarm value will start flashing (1.0mSv/h by default). Set the alarm value within
the 0.6–300μSv/h range by pressing (3). Press (5) to save the set dose rate alarm value.
Accumulated dose rate alarm
Press (3) and select DOSE Alarm screen.
Press (5) three times to select the dose alarm setting. The alarm value will start flashing (100mSv by default). Set the alarm value within the
1–3000μSv range by pressing (3). Press (5) to save the dose alarm value.
When the alarm threshold is reached, the device's buzzer (4) will start producing a beeping sound and the LED indicator (2) will be blinking in
green.
3