Descargar Imprimir esta página

Metabo SML 30 Manual Original página 8

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
en
ENGLISH
Never allow children to use the
device.
Children should be supervised to
ensure that they do not play with
the tool.
Keep children away from the
battery charger and the working
area!
Keep your battery charger out of
reach of children!
Pull out the mains plug immediately
if the battery charger starts to
smoke or flames emerge!
Do not insert objects into the
ventilation slots on the battery
charger – there is a danger of
electric shocks and short circuits!
Do not use faulty battery packs.
In areas with high metal dust
exposure do not charge any
battery packs with AIR COOLED
chargers.
5. Overview
See page 2. The illustrations are regarded as
exemplary for all devices.
1 Battery pack (not in scope of delivery)
2 Sliding seat
3 Operation display
4 Warning display
6. Initial Operation
Before commissioning, check that the rated
mains voltage and mains frequency stated
on the type plate match your power supply.
Devices like these that generate direct current can
influence simple earth leakage protection devices.
Use a type F or better, with a release current of max.
30 mA.
Before commissioning the charger, ensure
that the air slots are free. Minimum distance
to other objects is 5 cm!
6.1
Self-test
Plug in.
The warning display (4) and the operating indicator
(3) light up one after the other for approx. 1 second
and the installed fan runs for approx. 5 seconds.
8
7. Use
7.1
Charging battery pack
Push the battery pack completely to the stop on
the sliding seat (2).
The operating indicator (3) flashes.
Note: To have the charge level displayed on Li-ion
battery packs, first take the battery pack out of the
charger and then press the button on the battery
pack.
7.2
Conservation charge
Once the charging process has finished, the battery
charger automatically switches to conservation
mode.
The battery pack can remain in the battery charger
and is therefore always ready for use.
The operating display (3) lights up continuously.
8. Faults
8.1
Warning display (4) lights up
continuously
Battery pack is not charged. Excessive/insufficient
temperature. When the temperature of the battery
pack is between 0 °C and 50 °C, the charging
process begins automatically.
8.2
Warning display (4) flashes
• Battery pack is defective. Remove the battery
pack immediately from the charger.
• The battery pack was not pushed correctly onto
the sliding seat (2). See chapter 7.1.
9. Repairs
Repairs to the charger must only be carried out by
qualified electricians.
If the mains connection cable of this device is
damaged, it must be replaced by the manufacturer
or the Customer Service department of the
manufacturer or a similarly qualified person to
prevent endangering personnel and property.
With chargers in need of repair, please contact
Engelbert
Strauss.
strauss.works
8
For
addresses,
see

Publicidad

loading

Este manual también es adecuado para:

Sml 50