6. DMX INPUT: 3-pin male connector, used to connect the fogger directly to a DMX-controller or to the previous unit in
the DMX chain.
7. BREAKER: First locate and solve the problem that caused the breaker to be activated.When the problem is solved, push
the button to reset the breaker.
8. MAINS CONNECTOR: Insert the supplied mains cable here and connect it to in a mains wall socket with earth connection.
9. POWER SWITCH: TURN ON/OFF POWER.
10. FOG OUTPUT HOLE: Please connect fog hose and out output nozzle.
MEASURES
MENU SETTINGS
READY TO WORK
• This message will be shown on the display as soon as the machine is ready to be used.
• When the unit is just started up, the heating element of the fogger needs some time to warm up until
it reaches its ideal working temperature.
CONTROLLED via DMX
• 1 The DMX led (18) should be lit to indicate that a DMX-signal is received.
• 3. Press the [MENU] button until the DMX address appears on the display.
• 4. Use the UP/DONW buttons to set the desired DMX address.
• 5. The unit uses 2 DMX channels:
• Channel 1: fan speed (000-005: fan off ; 006-255: fan speed 1-100%)
• Channel 2: volume control (000-005: no output ; 006-255: volume 1-100%)
User Manual | TR-1500-LF by Triton Blue | January 2024 | www.triton-blue.com | Exclusive Professional Use
470 mm
310 mm
11.