ENG
Functions
Cerifications
Voltage and frequency
Power
Selectable temperature range
Operative temperature range
Storage temperature range
Insulation class
Ip protection
Dimensions
CHRONO
PROGRAM
(PROG)
0.- FIRST START
NOTE FOR THE FIRST START, SEE THE DEDICATED PARAGRAPH, ON NEXT PAGES
1.- STAND-BY
Press the [On / Stand-by] key to turn on the unit or activate the "Stand-by" mode.
When it is active, the set mode and temperature are displayed. During "Stand-by" the display shows
the symbol On / Off, the current time and the day of the week. (See Chrono mode section A)
NOTE: When the device enters "Stand-by" mode, 2 sounds of 0.5 seconds are emitted. When the
device is switched on, it emits two sounds lasting one second.
2.- COMFORT AND NIGHT MODE
Two different temperature levels can be set:
- "COMFORT" TEMPERATURE: this is the temperature used for the "Chrono", "Fil-Pilote" and
"Comfort" modes.
- "NIGHT" TEMPERATURE: this is the temperature used for "Night" and "Chrono" modes. The desired
temperature setting can be set by pressing the [+] and [-] buttons.
The temperature regulation range is between 7°C and 30°C. IMPORTANT!
The "Night" temperature is always lower than the "Comfort" temperature and the priority is assigned to
the "Comfort" temperature. For this reason the
"Night" temperature can be set in the range 7°C ÷ Selected "Comfort" Temperature, the "Comfort"
temperature can be set within the entire range: from 7º to 30°C.
20
STAND BY / ON
Comfort, Night, Antifreeze (7ºC), Stand-by, Chrono, Boost 2h, ECO, ASC,
Fil-pilote (on Class II), Open window
CE / UKCA
230VAC 50Hz
1000W
7°C ÷ 30°C (7°C in Antifreeze mode)
5°C ÷ 30°C
-10°C ÷ 50°C
Class II
Fixed unity IPx4
Fixed unity 110x110x30
Remote control Ø76x32
STAND BY / ON
UP
DOWN
PAIRING
(Back rear of the radiator)