NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING POINTS
WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT
Before any opera on on the float remember to disconnect the power supply from the main power.
Ÿ
Check that the maximum motor power does not exceed the float's electrical values.
Ÿ
In case of cable damage by the final user or installer, the float must be replaced.
Ÿ
Do not make any joint on the cable of the float switch, as immersion of such joints could cause short circuits or
Ÿ
electrical shocks.
USE:
The electronic controller is designed to work in clear and rain water. Supported on a flat surface, it remains anchored
to the bo om. It can detect the presence of water at 3mm ±1 from the floor.
The electronic regulator has two delay mes: start and stop (shutdown) which can be adjusted by the final customer
according to his needs of use. And thanks to the Schuko Piggy Back Plug (accessory sold separately) it can be
connected directly to a pump without the need of a tradi onal electronic panel.
TECHNICAL FEATURES:
- Opera ng temperature: max.+50°C (+122°F)
Features of automa c ac on: 1B (micro-disconnec ons in opera on)
SET DELAY TIMES:
The first me you connect the plug to the electrical system, the electronic controller will perform a 5 seconds
startup test to check the func oning.
Factory default delay me:
Star ng Delay Time: 5 seconds.
Ÿ
placed at the bo om of the electronic regulator.
Shutdown Delay Time: 30 seconds.
Ÿ
sensors.
Change the
Star ng/Delay Time (Fig.1)
close to the arrow stamped on the side of the electronic controller. 3. Connect the plug to turn on the pump. 4. Hold
the magne c key in posi on for how many seconds you wish to delay the star ng me (maximum 120 seconds). 5.
Once you got the desired delay me, remove the magne c key.
Change the
Shutdown Delay Time (Fig.2)
magne c key close to the electronic regulator in 5 seconds. The pump turns on. 7. Hold the magne c key in posi on
for how many seconds you wish to delay the shutdown me (maximum 120 seconds). 8. Once you got the desired
delay me, remove the magne c key.
If no ac on will occur within 5 seconds, the controller will record only the star ng delay me previously set up.
SWITCH BETWEEN EMPTYING AND FILLING:
It is possible to change the func oning from emptying to filling and vice versa. While the regulator is working, move
the magne c key close to the regulator for 1 second then remove it.
Connec on without plug
Black
L
Brown
N
Grey
M
Yellow/Green
ENGLISH
- Max depth: 10m (32,8 )
The pump turns on 5 seconds a er the water has raised touching the two sensors
The pump turns off 30 seconds a er the water has flowed down releasing the
1. Disconnect the plug from the electrical system 2. Put the magne c key
6. A er having set the Star ng Delay Time, you need to place the
- Protec on Grade: IP 68
- Pollu on Degree: 2
Connec on with Schuko Piggyback plug
Brown
N
Yellow/Green
Black
L
Grey