Descargar Imprimir esta página

Newa Slim NS 128 Instrucciones Y Garantía página 12

Led lámparas de alto rendimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
ASSEMBLY
Mounting LED supports
1) Insert both supports in a mirror image manner on the side of the LED bar without the power cord (fig. A).
2) Fasten the support on the end of the LED bar without the power cord, following the instructions shown in (fig.B). - Slide
the LED support up to 2-3 cm from the end edge of the LED bar without the cord (fig. B1).
- Turn the LED support clockwise (fig.B2).
- Push the LED support downwards until the LED lamp is placed into position and you hear a "CLICK" which ensures it has been
fixed (fig. B3).
3) Fix the support on the end of the LED bar with the power cord, following the instructions shown in (fig.C):
- Slide the LED support up to 2-3 cm from the end edge of the LED bar with the cable (fig. B1).
EN
- Turn the LED support counter-clockwise (fig.B2).
- Push the LED support downwards until the LED lamp is placed into position and you hear a "CLICK" which ensures it has been
fixed (fig. B3).
4) Slide the LED bar supports to the desired position so as to adjust the lamp length (fig. D).
Mounting on aquarium
Thanks to the adjustable supports, the NEWA Slim lamp can be adapted to the width of your aquarium.
To do this, extract the extendable brackets from the lamp body to the desired length.
Thanks to the supports, the LED lamp can also be placed directly on the edge of the open tank.
Make sure that the LED lamp remains at a distance of at least 15 mm from the maximum water level (fig. E).
FUNCTIONING PROCEDURES
WARNING: The power supply is not protected against water infiltration!
Do not mount the power supply under any circumstances on or inside the aquarium cover frame.
Insert the NEWA Slim lamp connector into the power supply socket (fig. F).
Screw the connector securely with the ring nut (fig. G).
Insert the plug into the electrical socket.
To turn on or off, use the switch located along the cord.
In order to prevent excessive exposure to light from causing the formation of algae, we recommend limiting the lighting time of
the NEWA Slim lamp to a maximum of 6-8 hours per day.
MAINTENANCE
Caution! Before carrying out any maintenance work, remove the power supply plug.
When cleaning, do not use hard objects or aggressive detergents.
Allow the LED lamp to cool off for at least 5 – 10 minutes before cleaning.
Clean the LED lamp as needed:
1. Disconnect the lamp from the power supply
2. Allow the LED lamp to cool off for at least 5 – 10 minutes.
3. When needed, wipe the LED lamp with a damp soft cloth.
Regular maintenance extends the life, and ensures the functioning, of the NEWA Slim lamp for a lengthy period.
CLEARING FAULTS
LED light does not illuminate.
Possible cause: Mains plug of mains socket not connected
Remedy: Insert the mains plug in the mains socket
Possible cause: Plug of LED light not connected to power supply unit.
Remedy: Connect the plug to the socket of the power supply unit.
12