Descargar Imprimir esta página

Hotpoint Ariston FKQ 89 EL .20 /HA Manual De Instrucciones página 18

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Electrical connection
GB
! Ovens equipped with a three-pole power supply
cable are designed to operate with alternating
current at the voltage and frequency indicated on
the data plate located on the appliance (see below).
Fitting the power supply cable
L
N
and the Yellow/Green wire to the terminal marked
(see diagram).
3. Secure the cable by fastening the clamp screw.
4. Close the cover of the terminal board.
Connecting the electricity supply cable to the
mains
Install a standardised plug corresponding to the
load indicated on the data plate (see table).
The appliance must be directly connected to the
mains using an omnipolar switch with a minimum
contact opening of 3 mm installed between the
appliance and the mains. The switch must be
suitable for the charge indicated and must comply
with current electrical regulations (the earthing wire
must not be interrupted by the switch). The supply
cable must be positioned so that it does not come
into contact with temperatures higher than 50°C at
any point (the back panel of the oven, for example).
! The installer must ensure that the correct electrical
connection has been performed and that it is fully
compliant with safety regulations.
18
1. Open the terminal
board by inserting a
screwdriver into the
side tabs of the cover.
Use the screwdriver as
a lever by pushing it
down to open the cover
(see diagram).
2. Install the power
supply cable by
loosening the cable
clamp screw and the
three wire contact
screws L-N-
.
Connect the wires to the
corresponding
terminals: the Blue wire
to the terminal marked
(N), the Brown wire to
the terminal marked (L)
Before connecting the appliance to the power
supply, make sure that:
• the appliance is earthed and the plug is compliant
with the law;
• the socket can withstand the maximum power of
the appliance, which is indicated on the data
plate (see below);
• the voltage is in the range between the values
indicated on the data plate (see below);
• the socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it.
Do not use extension cords or multiple sockets.
! Once the appliance has been installed, the power
supply cable and the electrical socket must be
easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced
by authorised technicians only (see Assistance).
! The manufacturer declines any liability should
The manufacturer declines any liability should
The manufacturer declines any liability should
The manufacturer declines any liability should
The manufacturer declines any liability should
these safety measures not be observed.
these safety measures not be observed.
these safety measures not be observed.
these safety measures not be observed.
these safety measures not be observed.
APPLIANCE SPECIFICATIONS
width 43.5 cm
Dimensions
height 32 cm
depth 41.5 cm
Volume
58 l
voltage: 220 - 240 V~ 50/60 Hz
Electrical
(see data plate)
connections
maximum power absorbed
2800 W
Directive 2002/40/EC on the label
of electric ovens. Standard EN 50304
ENERGY
Declared energy consumption
LABEL*
for Forced convection Class –
heating mode:
ECO.
* Without removable guide rails

Publicidad

loading