Descargar Imprimir esta página

Energizer Solar Peak 600 Manual Del Usuario página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

ENERGIZER SOLAR PEAK 600
Error Messages & Solutions
Icon
Icon Characteristics
Error code always on
High Temperature icon
flashes / Error code
Low Temperature icon
flashes / Error code
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Overload icon flashes /
Error code always on
Overload icon flashes /
Error code always on
Error code always on
Error code always on
Fault Description
Pressure difference is too large
Battery OTP
(over temperature protection) fault
always on
Battery UTP
(under temperature protection) fault
always on
OCP (over current protection) fault
Abnormal precharge
Battery under voltage fault
Abnormal INV battery voltage
Grid voltage or frequency fault
Abnormal INV BUS voltage
Abnormal INV output
INV discharge overload
Charge overload
INV output short
Automatic recovery after fault clearing; 3 consecutive locks within a
Shut down, after temperature recovery, rechargeable activation.
Shut down, after temperature recovery, rechargeable activation.
Remove the over-power device, and it will automatically recover
after the fault is cleared; if it is triggered continuously for 3 times
within 1 minute, it will be locked, and the recovery time will be
prolonged, and it can be recovered by powering on and off again.
Repeated charging failures or failure to charge,
Automatic recovery after the fault is cleared; if it is triggered 3 times
within 1 minute, it will be locked, and the recovery time will be
extended, and it can be recovered by powering on and off again.
The fault is cleared when the grid returns to normal.
Automatic recovery after the fault is cleared; if it is triggered 3 times
within 1 minute, it will be locked, and the recovery time will be
extended, and it can be recovered by powering on and off again.
Automatic recovery after the fault is cleared; if it is triggered 3 times
within 1 minute, it will be locked, and the recovery time will be
extended, and it can be recovered by powering on and off again.
Remove the over-power device, and it will automatically recover
after the fault is cleared; if it is triggered continuously for 3 times
within 1 minute, it will be locked, and the recovery time will be
prolonged, and it can be recovered by powering on and off again.
Automatic recovery after the fault is cleared; if it is triggered 3 times
within 1 minute, it will be locked, and the recovery time will be
extended, and it can be recovered by powering on and off again.
INV Tz
13
Solution
certain period of time, longer recovery time.
Power on and off again to clear the fault.
please contact customer service.
Auto recover after fault is cleared.
Fault will be cleared after reboot.
ENGLISH

Publicidad

loading

Productos relacionados para Energizer Solar Peak 600