Descargar Imprimir esta página

Electrolux EFA 12545 Manual De Instrucciones página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

This filter cannot be washed or regenerated, and must be replaced when the F touch control starts
to flash, or at least once every 4 months. The alarm is only triggered when the motor is on.
Enabling/Disabling the alarm signal
• In Recirculation Version Hoods, the Filter saturation Alarm must be enabled at the time of
installation or later.
• Switch off the lights and the motor.
• Disconnect the mains power supply to the hood by removing the motor unit power supply
cable connector, switching off the power supply at the Mains or turning the Main switch off.
• Restore the connection, pressing and holding T2.
• Release the touch control, touch controls L, T2 and F will light up normally.
• Within 3 seconds press the touch control F until the key itself flashes to confirm as follows:
• 2 flashes – Charcoal odour Filter saturation Alarm ENABLED
• 1 flash - Charcoal odour Filter saturation Alarm DISABLED
REPLACING THE CHARCOAL ODOUR FILTER
Reset the alarm signal
• Stop the motor.
• Press the touch control F for at least 4 seconds, until the touch
control T1 flashes.
Replace the Filter
• Remove the metal grease filters.
• Remove the saturated charcoal filter, turning the fasteners pro-
vided.
• Fit the new filter and fasten it its correct position.
• Put the metal grease filters in their seats.
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Replace the Support, fixing it in place with the two screws re-
moved as above.
EN
Odour filter (Recirculation Version)
Lighting
LIGHT REPLACEMENT
1
15
5

Publicidad

loading