3. INSPECT YOUR SHIPMENT
All pump controller devices are carefully tested, inspected, and
packaged to ensure their arrival in perfect condition. When the
device is received, examine it closely to make sure no damage
may have occurred in shipping. If damage is evident, report this
immediately to your shipping carrier and product dealer. The
shipping carrier assumes full responsibility for the shipment's
safe arrival. Any claim for damage to the shipment, either visible
or concealed, must be made through the shipping carrier.
Package Includes:
• Pump controller device
• Installation manual.
4. INSTALLATION
Location of the Pump Controller Device
Decide on a suitable location for the device installation, based
on the enclosure rating of the device.
WARNING: Liquid tight cables or conduit and fittings
must be used to maintain a Type 4 rating.
WARNING: This equipment must not be used by children
or people with reduced physical, sensory, or mental
abilities, or lacking in experience and expertise unless
supervised or instructed. Children may not use the
equipment, nor may they play with the unit or in the
immediate vicinity.
The device must be mounted in a vertical position (fig. 1).
Notice: Read and Follow all Instructions.
WARNING: Hazardous voltage can shock, burn, or
cause death.
CAUTION: Improper wiring can result in permanent
damage to the system. The pump connection must
comply with all applicable local codes.
CAUTION: If you are not sure of the proper electrical
connections, employ a competent electrician for the
installation. This ensures the installation complies with
all noted electrical codes. Disconnect power at the
electrical panel before making any electrical
connections. Supply voltage must be +/- 10% of
device nameplate voltage.
Low or high voltage can damage the device and will void the
warranty. Connect the device to the dedicated branch circuit
with no other appliances on it.
Do not operate the device unless it is grounded.
A fused disconnect switch or circuit breaker should be placed at
or near the pump as required by local electrical codes.
NOTICE: Before installing the device carefully check the
technical features and make sure they comply with those of the
pump and the system.
5. ELECTRICAL WIRING
WARNING: Serious or fatal electric shock may result
from failure to connect the pump and control to
the service entrance ground. Also, ground metal
plumbing and all other metal near the device. When
grounding these components, use a wire no smaller
than the power supply wires from the circuit breaker
to the device. To reduce the risk of electric shock,
disconnect power before working on or around the
water system.
INSTALLATION PROCEDURE-WIRING
Disconnect electrical power at the main breaker.
1.
Verify that the dedicated branch circuit for the device is
2.
equipped with a proper Listed fuse/Listed circuit breaker.
Remove the cover of the device by removing the six screws as
3.
shown in Fig. 5.
WARNING: The electrical wiring must be carried out
by qualified personnel in compliance with local
regulations. Observe all the safety standards and make
sure the device is properly grounded.
Follow all the indications on the electrical diagrams (fig. 8, 9, 10).

Publicidad

loading

Productos relacionados para Pearl BEST-CONTROL