Fault
Cause
The irrigation
Water tap is closed.
does not take
Battery depleted.
place in spite
of the pro-
Battery contacts oxidized.
gramming.
Filter gaskets blocked.
Valve does not
When the control unit is removed,
open / close.
the valve cannot open / close.
No display in-
Battery empty or contacts oxidised. Insert a new 9V battery (type
dication
Leakage at the
Filter gasket defective.
water connec-
The water connection at the water
tion.
tap has become loose.
Our Kärcher branch will be pleased to help you further in the case of questions or
faults. See address on the reverse.
Remove the battery from the battery compartment until the indication on the
display has completely gone out.
or
The settings are reset by pressing the OK button for 5 seconds.
Only use original accessories and spare parts, they ensure the safe and trouble-free
operation of the device.
For information about accessories and spare parts, please visit www.kaercher.com.
Operating pressure
Max. feed temperature
Ambient temperature
Battery type
Subject to technical changes.
28 English
Troubleshooting
Performing a reset
Accessories and Spare Parts
Technical specifications
Correction
Open tap.
Insert a new 9V battery (type
6LR61).
Clean the contacts.
Clean the filter gasket.
Attach the control unit to the
valve unit.
6LR61) or clean contacts.
Replace the filter gasket.
Reconnect the water connec-
tion.