Intended use

Underwater Power Supply 250, referred to in the following as "unit", may only be used as specified in the following:
 For use above and under water.
– Only use in conjunction with units intended by OASE for this purpose.
 Operation under observance of the technical data.
Use other than that intended
This unit can be dangerous and cause harm to persons if not used in accordance with these instructions. Any use not
in accordance with these instructions or modification(s) to the unit will void the limited warranty.

Installation and connection

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.

Protective measures:

 Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
 Isolate the unit before starting any work.
 Secure the unit to prevent unintentional switching on.
Set-up the unit
The unit can be submerged in water or set up in a dry location, but must always be protected from direct sunlight.
How to proceed:
 A
1. Place the unit on a firm base.
– If the unit is installed outside the water: Ensure that there is a safety distance of at least 1 ft (30 cm) from com-
bustible material.
2. Bolt the unit to the base.
Connect the unit
Note!
Never connect or disconnect the plugs and sockets of the connection cables when they are under load! This
could damage the contacts.
 First isolate the unit (switch off and disconnect from the power supply), then start work on the unit.
Note!
 Max. 80 Watt per output.
 Max. 240 Watt total.
 Do not exceed the max. connected load. ( Technical data)
 Adhere to the max. cable length per output ( Technical data)
 Only connect cables from OASE to the outputs.
 Close off any unused slots with blind plugs and rubber seals.
How to proceed:
 B
1. Remove the protection cap from the unit.
2. Fit the connector of the connection cable and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
3. Connect further connection cables in the same way.
4. Connect the unit to the mains voltage.
5. Check that the connected consumers are functioning faultlessly.

Optional accessories

OASE 24 V DC/01 connection cable 3.28 ft (1.0 m), 9.84 ft (3.0 m), 24.60 ft (7.5 m), 49.21 ft (15.0 m).