6. Technical Data
Technical Specifications
Range(usetargetplatefromabout50m)
Measuringaccuracyupto10m
(2
,standarddeviation)
Measuringunits
LaserClass
LaserType
Smallestunitdisplayed
Area,VolumeCalculations
ContinuousMeasurement
Min/MaxDistanceTracking
Displayilluminationandmulti-linedisplay
Beepindication
BLUETOOTH®4.0EDR
RangeofBLUETOOTH®
BLUETOOTH®withAppleiPod/iPhonesupport
BLUETOOTH®withSPPsupport
DustProtect/Splashproof
Historymeasurementrecords
KeyboardType
OperatingTemperature
StorageTemperature
Batteries
BatteryLife
Autolaserswitch-off
Autoinstrumentswitch-off
Dimension
Weight
8
* Use a target plate to increase the measurement range during
daylight or if the target has poor reflection properties!
** in favourable conditions (good target surface properties,
room temperature) up to 10 m (33 ft). In unfavourable
0.05to30m*(0.2into98ft*)
conditions, such as intense sunshine, poorly reflecting target
Typically:±1.5mm**
surface or high temperature variations, the deviation
(±1/16in**)
over distances above 10 m (33 ft) can increase by ± 0.15 mm/m
m,in,ft
(± 0.0018 in/ft).
ClassII
650nm,<1mW
1mm
7. Troubleshooting – Causes and Corrective Measures
Code
208
O
252
10m
253
255
IP54
20
SuperSoft-Touch(Longlife)
0°Cto40°C(32°Fto104°F)
-10°Cto60°C(14°Fto140°F)
TypeAAA2x1.5V
upto5,000measurements
after30seconds
after3min
135x33x24mm
80g
Laser Distance Meter/English
Cause
Received signal too weak,
Use target plate
measurement time too long.
Distance >50m
Temperature too high
Cool down instrument
Temperature too low
Warm up instrument
Hardware error
Switch on/off the
device several times,
If the symbol still
appears, please contact
your dealer for
assistance.
Corrective measure