TECHNICAL CHARACTERISTICS:
Voltage:
220 V~
Frequency:
60 Hz
Current:
10 A
Speed:
3 450 RPM
Motor Rated Power:
3 Hp
Maximum Motor Power:
4 Hp
Maximum Pressure:
116 PSI
Tank Capacity:
31.7 Gal
IP Grade:
IP20
Air Flow:
7.7 CFM - 40 PSI
5.7 CFM - 90 PSI
Power Cord Grips Type: Y
All conductors are: 1.5 mm
Build quality: Basic insulation.
Insulation quality: Class l
Thermal insulation of motor winding: Class B
CAUTION
To avoid risk of electrical shock or serious accident,
if power cord gets damaged it shall be repaired by the manufacturer
or by Truper
Authorized Service Center
®
Power cord grips used in this product: Type"Y".
Assembly design in this product causes insulation to be affected by
liquid spills or splashing.
WARNING
power circuits shall be disconnected.
WARNING
extensions with compressors. Using that type of extension
cause power drops resulting in motor potency loss and
overheating. Instead of using an extension cord increase
the compressor's action scope connecting a longer hose
into the outlet. Connect additional hose lengths as needed.
BELT DRIVE AIR COMPRESSORS.
- Do not use compressed air to clean clothes.
- Do not apply compressed air directly to skin.
- Do not apply compressed air for breathing purposes unless the air
is ltered with a lter speci cally for built to that purpose.
- Do not use open-air piping. It could lash out and cause injuries.
- Do not use ammable liquids to clean the compressor.
- Do not use an open re to inspect inside the compressor or the
pressure deposit.
- Wear eye protection when using compressed air to clean the unit.
- Use caution not to blow particles towards people: always use an
air gun for cleaning.
- Double-check all the auxiliary xtures are functioning adequately
and have the right capacity for the application.
- Inspect regularly that all covers are xed and rmly set.
- Replace all parts, tools and accessories when un t for a safe
operation.
- Install a check-valve or a cut valve in the inlet piping in case
compressor shall be parallel coupled with a second compressor
or if it will be connected to an air supply system.
- Double-check all piping and hoses connected to the compressor
have the right diameter, and, adequate resistance for the maximum
pressure delivered by the compressor.
- Install the compressor making available an adequate ventilation
air supply towards the unit. Use care not to restrict air ducts through
the inlets in the cover and motor fan.
4
ENGLISH
x 3C with 221 ºF Insulating Temperature
2
Before gaining access to terminals, all
We do not recommend using power cord
INSPECT:
Inspect the belts rotation direction during the initial start up. Verify
any modi cation in the electric components' or connections.
Turn off the compressor and disconnect from the power outlet.
Ventilate completely before disassembling any component or making
any maintenance service.
INSTALLATION AND VENTILATION
To service the compressor allow adequate access and free space
up and around the unit. It needs adequate protection against weather.
Good ventilation is essential. To gain maximum ef ciency admission
air shall be as cold and clean as possible (37.4 ºF drop in temperature
will increase 1% the delivered air volume). Gas impurities and
particles, abrasive dust and corrosive gasses are especially harmful.
The exhaust vapors are hazardous if compressed air is used to supply
breathing devices.
Set the compressor as far away as possible from the work areas to
prevent from suctioning particles generated by the job (paint, dust,
etc.)
WARNING
This unit SHOULD BE USED with
220 V~ - 240 V~ feeding tension.
Using a different TENSION WILL
SEVERELY DAMAGE
the unit.
CONNECTION TO THE MAIN POWER SUPPLY
he compressor shall be set as close as possible to the main power
supply. Double-check the power supply matches the voltage indicated
in the motor nameplate.
WARNING
This unit must be grounded.
The power cables are coded with the following
CAUTION
colors:
GREEN AND YELLOW
GROUND
BLUE
CURRENT
BROWN
CURRENT
This tool is in compliance with
the Official Mexican Standard
(NOM - Norma Oficial Mexicana).