Troubleshooting
Error codes
Code
Description
What to do
E01
DC output overload
After the overload is removed, short press the DC button
E02
DC output short circuit
After the short circuit is removed, short press the Power button
E03
AC overload/short circuit
After the overload/short circuit is removed, short press the AC button
E04
AC output over temperature
When temperature returns to normal, short press the AC button
E05
PD overload/short circuit
After the overload/short circuit is removed, plug it again
E06
Battery temperature is too high
The failure code clears automatically when temperature returns to normal.
E07
Battery temperature is too low
The failure code clears automatically when temperature returns to normal.
E08
USB overload/short circuit
After the overload/short circuit is removed, short press the Power button
E09
DC charging over-voltage
The failure code clears automatically when voltage returns to normal.
The failure code clears automatically when voltage returns to normal.
E10
DC charging low voltage
E11
Battery charge/discharge overheated
The failure code clears automatically when temperature returns to normal.
Attention!
Please comply with the following security instructions
1. When you do not use the product for a long time, you are advised to keep the battery at a certain capacity and
charge the product at least once every three months.
2. The device may heat up slightly during use or charging; it is normal, not a failure.
3. Store this power station in a dry place away from humidity, high temperatures and flammable or corrosive materials.
5. Do not scrub with soap or detergent.
6. When you find that the battery is swollen, leaking, or releasing an odd smell, please stop using it immediately.
7. Avoid dropping this unit or subject it to excessive shock or vibration.
8. Please place the product out of the reach of children. If children need to use the portable power station, it must be
operated by parents according to the instruction manual.
9. Please do not dump or burn the discarded portable power station. Please take care of the environment.
Technical specifications
FPP-T300
Capacity
236.25Wh (11.25V 21Ah)
Total outlets
9 outlets (7 output, 1 input, and 1 input/output)
LED lights
LED lamp (6W — white light — 5 modes: static hi-lit, static mid-lit,
slow-paced strobe, fast-paced strobe, off)
Input
DC charge input power (DC power adapter)
12-30V/4A
Solar charge input
MPPT 12-30V, 4A, 64W max.
Car charger
12V/4A
Output
AC output capacity
300W total (Surge 600W)
Sine wave
Pure sine wave
AC output voltage
(x2) 120VAC, 50/60Hz
USB-A output
(x1) 5VDC, 2.4A, 12W max.
USB-A fast charge
(x1) 5V/3A, 9V/2A, 12V/1.5A, 18W max.
USB-C output
(x1) 5V/3A, 9V/3A, 15V/3A, 20V/3.25A, 65W max.
DC 5.5 x 2.1mm
(x2) 120W, 12VDC, 10A max.
Car power output
(x1) 120W, 12VDC, 10A max.
Charging / Batteries
Battery
236.25Wh (11.25V 21Ah) LiMnFePO4
Charge method
PD + adapter, 12V car adapter, MPPT solar
Charging time from 0 to 100%
PD (65W) + DC (64W)
2 h
DC (64W)
4.5 h
12V/4A
5.5 h
Cell chemistry
LMFP
Life span
3000 cycles at 80% + capacity
Battery runtime scenarios (from 100 to 0%)
*
Outdoor light (5W)
40 h
Smartphone (10W)
22 times
LED light bulb (10W)
19 h
10" Tablet (19W)
14 times
Speaker (30W)
11 times
Camera (40W)
7 times
CPAP (40W)
6 h
Drone (50W)
6 times
Portable fan (50W)
4 h
Notebook (60W)
5 times
Incandescent light bulb (60W)
3.4 h
Mini fridge (60W)
4 h
LED TV (110W)
1.8 h
Blender (500W)
0.5 h
Drill (500W)
0.5 h