Symptom
• E2 appears on the display, the device turns
off automatically and the display shows error
E2 until the fault is repaired. To remove it
from the display, press the ON/OFF key
once on the keyboard or the remote control.
• One or both compressors do not work.
• The unit does not respond to the remote
control.
• Centrifugal blower or condenser fan blocked
in short circuit or disconnected.
• 24V - 7,5A / 12V - 10A fuse in the centrifugal
blower or condenser fan blown.
• Electronic board faulty.
• Bad connection of the terminals.
• Electronic module/s on the compressor/s
faulty.
• Compressor/s faulty.
• Too much pressure in the circuit due to
excess load or very high temperature.
• Remote control not programmed.
• Remote control battery flat; the LED does
not come on.
• Electronic control faulty.